Your browser doesn't support javascript.
loading
Solid-phase extraction based on amino-functionalized graphene oxide nanocomposites for analysis of short-chain perfluorinated alkyl acids in human serum by ion chromatography mass spectrometry.
Zhong, Zhixiong; Li, Gongke; Guo, Lingchuan; Yao, Jing; Liu, Zhe; Deng, Jianchao.
  • Zhong Z; Center for Disease Control and Prevention of Guangdong Province, Guangzhou, China.
  • Li G; School of Chemistry, Sun Yat-sen University, Guangzhou, China.
  • Guo L; Center for Disease Control and Prevention of Guangdong Province, Guangzhou, China.
  • Yao J; Center for Disease Control and Prevention of Guangdong Province, Guangzhou, China.
  • Liu Z; Center for Disease Control and Prevention of Guangdong Province, Guangzhou, China.
  • Deng J; Department of Food Engineering and Quality Safety South China Sea Fisheries Research Institute, China.
Biomed Chromatogr ; 32(7): e4223, 2018 Jul.
Article en En | MEDLINE | ID: mdl-29495074
ABSTRACT
A highly sensitive method was developed for the analysis of short-chain perfluorinated alkyl acids (PFAAs) in serum samples using solid-phase extraction (SPE) coupled with ion chromatography-electrospray ionization-mass spectrometry. The synthesized amino-functionalized graphene oxide nanocomposites were used as an SPE sorbent for the enrichment of trace analytes and purification of samples. They exhibited high selectivity to polar compounds. The suppressor was employed to remove counterions and reduce background signals of mobile phase. These two crucial steps could effectively eliminate matrix effects and enhance analytical sensitivity. The lowest limits of quantification were 2.0 µg L-1 for perfluorobutanoic acid and perfluorovaleric acid, 1.0 µg L-1 for perfluorocaproic acid and 0.50 µg L-1 for perfluorobutane sulfonic acid, respectively. The procedure was successfully applied for determination of trace PFAAs in 25 serum samples. Mean recoveries ranged from 86.3 to 101.4% with relative standard deviations of 1.6-6.8%. The method allowed an excellent separation and quantification of short-chain PFAAs that were difficult to analyze by conventional chromatography.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Cromatografía por Intercambio Iónico / Extracción en Fase Sólida / Nanocompuestos / Fluorocarburos / Grafito Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Cromatografía por Intercambio Iónico / Extracción en Fase Sólida / Nanocompuestos / Fluorocarburos / Grafito Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Año: 2018 Tipo del documento: Article