Your browser doesn't support javascript.
loading
Comparison of an In Vitro Diagnostic Next-Generation Sequencing Assay with Sanger Sequencing for HIV-1 Genotypic Resistance Testing.
Tzou, Philip L; Ariyaratne, Pramila; Varghese, Vici; Lee, Charlie; Rakhmanaliev, Elian; Villy, Carolin; Yee, Meiqi; Tan, Kevin; Michel, Gerd; Pinsky, Benjamin A; Shafer, Robert W.
  • Tzou PL; Division of Infectious Diseases, Stanford University School of Medicine, Stanford, California, USA philiptz@stanford.edu rshafer@stanford.edu.
  • Ariyaratne P; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Varghese V; Division of Infectious Diseases, Stanford University School of Medicine, Stanford, California, USA.
  • Lee C; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Rakhmanaliev E; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Villy C; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Yee M; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Tan K; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Michel G; Vela Diagnostics, Singapore Science Park II, Singapore.
  • Pinsky BA; Division of Infectious Diseases, Stanford University School of Medicine, Stanford, California, USA.
  • Shafer RW; Department of Pathology, Stanford University School of Medicine, Stanford, California, USA.
J Clin Microbiol ; 56(6)2018 06.
Article en En | MEDLINE | ID: mdl-29618499
ABSTRACT
The ability of next-generation sequencing (NGS) technologies to detect low frequency HIV-1 drug resistance mutations (DRMs) not detected by dideoxynucleotide Sanger sequencing has potential advantages for improved patient outcomes. We compared the performance of an in vitro diagnostic (IVD) NGS assay, the Sentosa SQ HIV genotyping assay for HIV-1 genotypic resistance testing, with Sanger sequencing on 138 protease/reverse transcriptase (RT) and 39 integrase sequences. The NGS assay used a 5% threshold for reporting low-frequency variants. The level of complete plus partial nucleotide sequence concordance between Sanger sequencing and NGS was 99.9%. Among the 138 protease/RT sequences, a mean of 6.4 DRMs was identified by both Sanger and NGS, a mean of 0.5 DRM was detected by NGS alone, and a mean of 0.1 DRM was detected by Sanger sequencing alone. Among the 39 integrase sequences, a mean of 1.6 DRMs was detected by both Sanger sequencing and NGS and a mean of 0.15 DRM was detected by NGS alone. Compared with Sanger sequencing, NGS estimated higher levels of resistance to one or more antiretroviral drugs for 18.2% of protease/RT sequences and 5.1% of integrase sequences. There was little evidence for technical artifacts in the NGS sequences, but the G-to-A hypermutation was detected in three samples. In conclusion, the IVD NGS assay evaluated in this study was highly concordant with Sanger sequencing. At the 5% threshold for reporting minority variants, NGS appeared to attain a modestly increased sensitivity for detecting low-frequency DRMs without compromising sequence accuracy.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: VIH-1 / Farmacorresistencia Viral / Secuenciación de Nucleótidos de Alto Rendimiento / Mutación Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: VIH-1 / Farmacorresistencia Viral / Secuenciación de Nucleótidos de Alto Rendimiento / Mutación Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2018 Tipo del documento: Article