Your browser doesn't support javascript.
loading
Chemical exchange rotation transfer (CERT) on human brain at 3 Tesla.
Lin, Eugene C; Li, Hua; Zu, Zhongliang; Louie, Elizabeth A; Lankford, Christopher L; Dortch, Richard D; Does, Mark D; Gore, John C; Gochberg, Daniel F.
  • Lin EC; Vanderbilt University Institute of Imaging Science, Nashville, Tennessee.
  • Li H; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Zu Z; Vanderbilt University Institute of Imaging Science, Nashville, Tennessee.
  • Louie EA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Lankford CL; Vanderbilt University Institute of Imaging Science, Nashville, Tennessee.
  • Dortch RD; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Does MD; Vanderbilt University Institute of Imaging Science, Nashville, Tennessee.
  • Gore JC; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
  • Gochberg DF; Vanderbilt University Institute of Imaging Science, Nashville, Tennessee.
Magn Reson Med ; 80(6): 2609-2617, 2018 12.
Article en En | MEDLINE | ID: mdl-29802641
ABSTRACT

PURPOSE:

To test the ability of a novel pulse sequence applied in vivo at 3 Tesla to separate the contributions to the water signal from amide proton transfer (APT) and relayed nuclear Overhauser enhancement (rNOE) from background direct water saturation and semisolid magnetization transfer (MT). The lack of such signal source isolation has confounded conventional chemical exchange saturation transfer (CEST) imaging.

METHODS:

We quantified APT and rNOE signals using a chemical exchange rotation transfer (CERT) metric, MTRdouble . A range of duty cycles and average irradiation powers were applied, and results were compared with conventional CEST analyses using asymmetry (MTRasym ) and extrapolated magnetization transfer (EMR).

RESULTS:

Our results indicate that MTRdouble is more specific than MTRasym and, because it requires as few as 3 data points, is more rapid than methods requiring a complete Z-spectrum, such as EMR. In white matter, APT (1.5 ± 0.5%) and rNOE (2.1 ± 0.7%) were quantified by using MTRdouble with a 30% duty cycle and a 0.5-µT average power. In addition, our results suggest that MTRdouble is insensitive to B0 inhomogeneity, further magnifying its speed advantage over CEST metrics that require a separate B0 measurement. However, MTRdouble still has nontrivial sensitivity to B1 inhomogeneities.

CONCLUSION:

We demonstrated that MTRdouble is an alternative metric to evaluate APT and rNOE, which is fast, robust to B0 inhomogeneity, and easy to process.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Encéfalo / Mapeo Encefálico / Neoplasias Encefálicas / Imagen por Resonancia Magnética Tipo de estudio: Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Encéfalo / Mapeo Encefálico / Neoplasias Encefálicas / Imagen por Resonancia Magnética Tipo de estudio: Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Año: 2018 Tipo del documento: Article