Your browser doesn't support javascript.
loading
Neuroform Atlas stent deployment through the Barrel vascular reconstruction device for the treatment of a wide-necked acutely ruptured basilar aneurysm.
Valente, Iacopo; D'Argento, Francesco; Alexandre, Andrea; Lozupone, Emilio; Garignano, Giuseppe; Pedicelli, Alessandro.
  • Valente I; 1 UOC Radiologia e Neuroradiologia, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • D'Argento F; 1 UOC Radiologia e Neuroradiologia, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Alexandre A; 1 UOC Radiologia e Neuroradiologia, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Lozupone E; 1 UOC Radiologia e Neuroradiologia, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
  • Garignano G; 2 Istituto di Radiologia, Università Cattolica del Sacro Cuore, Roma, Italy.
  • Pedicelli A; 1 UOC Radiologia e Neuroradiologia, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, Roma, Italy.
Interv Neuroradiol ; 25(1): 27-30, 2019 Feb.
Article en En | MEDLINE | ID: mdl-30235957
ABSTRACT

BACKGROUND:

The Barrel vascular reconstruction device is an electrolytically detachable laser-cut closed-cell stent used for neck reconstruction in wide-necked bifurcation aneurysms to support coiling without necessitating dual stent implantation. The purpose is to lower the metal-to-artery ratio and its inherent risk of thromboembolic complications of multiple stents. CASE DESCRIPTION A 53-year-old woman presenting with subarachnoid hemorrhage due to acutely ruptured basilar tip aneurysm underwent emergency endovascular embolization with the Barrel vascular reconstruction device. Since the stent did not cover the entire neck of the aneurysm, an Atlas stent was released in a Y configuration through the Barrel. The Neuroform Atlas correctly opened through the Barrel and allowed the complete exclusion of the aneurysm.

CONCLUSION:

If necessary, releasing a Neuroform Atlas through a Barrel vascular reconstruction device is a feasible technique.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Arteria Basilar / Stents / Aneurisma Intracraneal / Aneurisma Roto / Procedimientos Endovasculares Límite: Female / Humans / Middle aged Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Arteria Basilar / Stents / Aneurisma Intracraneal / Aneurisma Roto / Procedimientos Endovasculares Límite: Female / Humans / Middle aged Idioma: En Año: 2019 Tipo del documento: Article