Your browser doesn't support javascript.
loading
Measurement of Atmospheric Dimethyl Sulfide with a Distributed Feedback Interband Cascade Laser.
Wang, Shuanke; Du, Zhenhui; Yuan, Liming; Ma, Yiwen; Wang, Xiaoyu; Han, Ruiyan; Meng, Shuo.
  • Wang S; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. wangshuanke@tju.edu.cn.
  • Du Z; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. duzhenhui@tju.edu.cn.
  • Yuan L; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. yuanliming@tju.edu.cn.
  • Ma Y; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. yiwenma@tju.edu.cn.
  • Wang X; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. wangxiaoyu9453@tju.edu.cn.
  • Han R; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. hanruiyan@tju.edu.cn.
  • Meng S; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China. mengsh@tju.edu.cn.
Sensors (Basel) ; 18(10)2018 Sep 24.
Article en En | MEDLINE | ID: mdl-30249970
ABSTRACT
This paper presents a mid-infrared dimethyl sulfide (CH3SCH3, DMS) sensor based on tunable laser absorption spectroscopy with a distributed feedback interband cascade laser to measure DMS in the atmosphere. Different from previous work, in which only DMS was tested and under pure nitrogen conditions, we measured DMS mixed by common air to establish the actual atmospheric measurement environment. Moreover, we used tunable laser absorption spectroscopy with spectral fitting to enable multi-species (i.e., DMS, CH4, and H2O) measurement simultaneously. Meanwhile, we used empirical mode decomposition and greatly reduced the interference of optical fringes and noise. The sensor performances were evaluated with atmospheric mixture in laboratory conditions. The sensor's measurement uncertainties of DMS, CH4, and H2O were as low as 80 ppb, 20 ppb, and 0.01% with an integration time 1 s, respectively. The sensor possessed a very low detection limit of 9.6 ppb with an integration time of 164 s for DMS, corresponding to an absorbance of 7.4 × 10-6, which showed a good anti-interference ability and stable performance after optical interference removal. We demonstrated that the sensor can be used for DMS measurement, as well as multi-species atmospheric measurements of DMS, H2O, and CH4 simultaneously.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2018 Tipo del documento: Article