Your browser doesn't support javascript.
loading
Determination of linear and cyclic volatile methyl siloxanes in biogas and biomethane by solid-phase microextraction and gas chromatography-mass spectrometry.
Ghidotti, Michele; Fabbri, Daniele; Torri, Cristian.
  • Ghidotti M; Interdepartmental Centre for Industrial Research "FRAME" and Department of Chemistry "Giacomo Ciamician", University of Bologna, Ravenna Campus, via S.Alberto 163, I-48123 Ravenna, Italy. Electronic address: michele.ghidotti2@unibo.it.
  • Fabbri D; Interdepartmental Centre for Industrial Research "FRAME" and Department of Chemistry "Giacomo Ciamician", University of Bologna, Ravenna Campus, via S.Alberto 163, I-48123 Ravenna, Italy.
  • Torri C; Interdepartmental Centre for Industrial Research "FRAME" and Department of Chemistry "Giacomo Ciamician", University of Bologna, Ravenna Campus, via S.Alberto 163, I-48123 Ravenna, Italy.
Talanta ; 195: 258-264, 2019 Apr 01.
Article en En | MEDLINE | ID: mdl-30625541
ABSTRACT
A new method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of seven linear (L2 - L5) and cyclic (D3 - D5) volatile methyl siloxanes (VMS) in biogas and biomethane, directly collected into Tedlar® bags (Tedlar SPME) from anaerobic digesters and wastewater treatment plants. The method was employed to monitor VMS content in biomethane produced by biogas upgrading with a pilot-plant membrane unit and provided adequate limits of quantification (< 0.05 mg m-3) to detect trace siloxane impurities. Tedlar SPME was validated against a standard procedure based on indirect sampling of gas streams with sorbent tubes followed by solvent extraction and GC-MS. Method precision (RSD) on total and individual VMS concentrations was lower than 10%, while RSD values of the standard procedure were higher than 20%. Tedlar SPME suitably revealed high VMS levels, expressed as total volatile silicon (> 1 mgSim-3), in wastewater biogas and provided a more efficient sampling of heavier VMS in comparison to the sorbent tubes method. At low values (< 0.1 mgSim-3) typical of wood waste biogas and biomethane, no statistically significant differences were observed between the two methods. Overall, Tedlar SPME simplified the analytical procedure by reducing the procedural steps, avoiding the use of solvents and demonstrated its applicability for testing the quality of biomethane as advanced biofuel.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2019 Tipo del documento: Article