Your browser doesn't support javascript.
loading
Effect of timing of post space preparation on the apical seal when using different sealers and obturation techniques.
Nagas, Emre; Karaduman, Elcin; Sahin, Cem; Uyanik, Ozgur; Canay, Senay.
  • Nagas E; Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.
  • Karaduman E; Department of Prostodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.
  • Sahin C; School of Dental Technology, Hacettepe University, Ankara, Turkey.
  • Uyanik O; Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.
  • Canay S; Department of Prostodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.
J Dent Sci ; 11(1): 79-82, 2016 Mar.
Article en En | MEDLINE | ID: mdl-30894950
ABSTRACT
BACKGROUND/

PURPOSE:

To prepare the post apace, some of the root-canal filling material has to be removed, which can affect the apical seal. The aim of this study was to compare the effect of immediate post space preparation to that of delayed post space preparation on apical sealing using three different endodontic sealers and obturation techniques. MATERIALS AND

METHODS:

In total, 90 decrowned single-rooted human teeth were studied. After root canals were prepared with 0.06 tapered nickel-titanium rotary files to size 30, the roots were categorized randomly into three experimental groups according to the obturation

material:

(1) AH plus/gutta-percha; (2) Sealite Ultra/gutta-percha; and (3) Epiphany/Resilon. Furthermore in all groups, specimens were categorized randomly into three subgroups according to the obturation technique (n = 10) (1) single cone; (2) cold lateral compaction; and (3) System B + Obtura. After root-canal filling, post space preparation was immediately performed in Group 1, after 24 hours in Group 2, and after 7 days in Group 3. Apical leakage was measured using the fluid-filtration method. Statistical analysis was performed using the Kruskal-Wallis test and Wilcoxon signed ranks test at P < 0.001.

RESULTS:

Regardless of the obturation technique and sealers used, significantly better (P < 0.001) sealing was achieved at the apical ends using delayed post space preparation than with immediate post preparation. The obturation techniques tested did not significantly affect leakage values. The following statistical ranking of fluid filtration values was obtained for the obturation materials Epiphany/Resilon > Sealite Ultra/gutta-percha > AH plus/gutta-percha (P < 0.001).

CONCLUSION:

To reduce apical leakage, clinicians should use AH plus together with any of the obturation techniques after 7 days of obturation.