REDUCTION OF STAFF RADIATION DOSE IN PROSTATIC ARTERY EMBOLISATION.
Andrade, G; Garzón, W J; Khoury, H J; Savignon, J; de Barros, V S M; Fernandes, J L; Abud, D G.
  • Andrade G; Hospital da Restauração, Av. Gov. Agamenon Magalhães, s/n-Derby, Recife, Brazil.
  • Garzón WJ; Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da USP, Av. Bandeirantes, 3900-Vila Monte Alegre, Ribeirão Preto, Brazil.
  • Khoury HJ; Laboratorio de Radiaciones Nucleares, Universidad Pedagógica y Tecnológica de Colombia, Avenida Central del Norte 39-115, Tunja, Colombia.
  • Savignon J; Departamento de Energía Nuclear, Universidade Federal de Pernambuco, Av. Prof. Luiz Freire, 1000-Cidade Universitaria, Recife, Brazil.
  • de Barros VSM; Departamento de Energía Nuclear, Universidade Federal de Pernambuco, Av. Prof. Luiz Freire, 1000-Cidade Universitaria, Recife, Brazil.
  • Fernandes JL; Departamento de Energía Nuclear, Universidade Federal de Pernambuco, Av. Prof. Luiz Freire, 1000-Cidade Universitaria, Recife, Brazil.
  • Abud DG; Siemens Healthcare Diagnósticos Ltda, Avdas Americas, 3500, Rio de Janeiro, Brazil.
Radiat Prot Dosimetry ; 187(1): 1-7, 2019 Dec 31.
Article en En | MEDLINE | ID: mdl-31034554
ABSTRACT
Prostatic artery embolisation (PAE) is used to treat patients with benign prostatic hyperplasia and with lower urinary obstructive tract symptoms. It is an interventional procedure which uses fluoroscopy equipment and can result in exposure to high doses of radiation in patients and staff. We aimed to demonstrate the reduction of radiation doses received by staff during PAE by implementing an optimised protocol called Radiation Exposure Curtailment for Embolisation (RECiFE). This protocol was implemented in cooperation with the medical team and technical team using Siemens Combined Applications to Reduce Exposure (CARE) protocol. The results showed approximately 83% reduction in the radiation doses received by the main physician during PAE. Thus, by adjusting the acquisition parameters of the angiographic equipment and implementing the RECiFE protocol, it is possible to optimise the PAE procedure and reduce the staff radiation dose.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Hiperplasia Prostática / Protección Radiológica / Radiografía Intervencional / Exposición Profesional / Exposición a la Radiación / Fantasmas de Imagen / Embolización Terapéutica Límite: Humans / Male País como asunto: America do sul / Brasil Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Hiperplasia Prostática / Protección Radiológica / Radiografía Intervencional / Exposición Profesional / Exposición a la Radiación / Fantasmas de Imagen / Embolización Terapéutica Límite: Humans / Male País como asunto: America do sul / Brasil Idioma: En Año: 2019 Tipo del documento: Article