Your browser doesn't support javascript.
loading
Method comparison study of the Elecsys® ß-Amyloid (1-42) CSF assay versus comparator assays and LC-MS/MS.
Shaw, Leslie M; Hansson, Oskar; Manuilova, Ekaterina; Masters, Colin L; Doecke, James D; Li, Qiao-Xin; Rutz, Sandra; Widmann, Monika; Leinenbach, Andreas; Blennow, Kaj.
  • Shaw LM; Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, 3400 Civic Center Blvd, Philadelphia, PA 19104, USA. Electronic address: leslie.shaw2@uphs.upenn.edu.
  • Hansson O; Clinical Memory Research Unit, Lund University, VO Minnessjukdomar, Simrisbanv 14/4, 212 24 Malmö, Sweden; Memory Clinic, Skåne University Hospital, Inga Marie Nilssons gata 47, 214 21 Malmö, Sweden. Electronic address: oskar.hansson@med.lu.se.
  • Manuilova E; Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany. Electronic address: ekaterina.manuilova@roche.com.
  • Masters CL; The Florey Institute of Neuroscience and Mental Health, University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia. Electronic address: c.masters@unimelb.edu.au.
  • Doecke JD; The Commonwealth Scientific and Industrial Research Organisation/Australian E-Health Research Centre, Butterfield St & Bowen Bridge Rd, Herston, QLD 4029, Australia. Electronic address: james.doecke@csiro.au.
  • Li QX; The Florey Institute of Neuroscience and Mental Health, University of Melbourne, 30 Royal Parade, Parkville, VIC 3052, Australia. Electronic address: q.li@unimelb.edu.au.
  • Rutz S; Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany. Electronic address: sandra.rutz@roche.com.
  • Widmann M; Roche Diagnostics GmbH, Sandhofer Str. 116, 68305 Mannheim, Germany. Electronic address: monika.widmann@roche.com.
  • Leinenbach A; Roche Diagnostics GmbH, Inselkammerstraße 8, 82008 Unterhaching, Munich, Germany. Electronic address: andreas.leinenbach@roche.com.
  • Blennow K; Clinical Neurochemistry Laboratory, Sahlgrenska University Hospital, Göteborgsvägen 31, 431 80 Mölndal, Sweden; Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry, The Sahlgrenska Academy at University of Gothenburg, Wallinsgatan 6, 431 41 Mölndal, Sweden. Electron
Clin Biochem ; 72: 7-14, 2019 Oct.
Article en En | MEDLINE | ID: mdl-31129181
ABSTRACT

BACKGROUND:

Alzheimer's disease (AD) biomarkers, such as cerebrospinal fluid (CSF) amyloid-ß (1-42; Aß42), can provide high diagnostic accuracy. Several immunoassays are available for Aß42 quantitation, but standardisation across assays remains an issue. We compared the Elecsys® ß-Amyloid (1-42) CSF assay with three assays and two liquid chromatography tandem mass spectrometry (LC-MS/MS) methods.

METHODS:

Three method comparison studies evaluated the correlation between the Elecsys® ß-Amyloid (1-42) CSF assay versus INNOTEST® ß-AMYLOID(1-42) (860 samples) and the Roche Diagnostics-developed LC-MS/MS method (250 samples); INNO-BIA AlzBio3 and the University of Pennsylvania (UPenn)-developed LC-MS/MS method (250 samples); and ADx-EUROIMMUN Beta-Amyloid (1-42) enzyme-linked immunosorbent assay (ELISA) (49 samples).

RESULTS:

High correlation was demonstrated between Elecsys® ß-Amyloid (1-42) CSF and comparator assays INNOTEST® ß-AMYLOID(1-42) (Spearman's ρ, 0.954); INNO-BIA AlzBio3 (Spearman's ρ, 0.864); ADx-EUROIMMUN Beta-Amyloid (1-42) ELISA (Pearson's r, 0.925). Elecsys® assay and LC-MS/MS measurements were highly correlated Pearson's r, 0.949 (Roche Diagnostics-developed method) and 0.943 (UPenn-developed method).

CONCLUSION:

Findings from this multicentre evaluation further support use of the Elecsys® ß-Amyloid (1-42) CSF assay to aid AD diagnosis. CSF-based certified reference materials should improve agreement across assays and mass spectrometry-based methods, which is essential to establish a global uniform CSF Aß42 cut-off to detect amyloid pathology.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fragmentos de Péptidos / Inmunoensayo / Péptidos beta-Amiloides / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fragmentos de Péptidos / Inmunoensayo / Péptidos beta-Amiloides / Técnicas Electroquímicas Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article