Your browser doesn't support javascript.
loading
Multiresidue Pesticides Analysis of Vegetables in Vietnam by Ultrahigh-Performance Liquid Chromatography in Combination with High-Resolution Mass Spectrometry (UPLC-Orbitrap MS).
Vu-Duc, Nam; Nguyen-Quang, Trung; Le-Minh, Thuy; Nguyen-Thi, Xuyen; Tran, Tri Manh; Vu, Hai Anh; Nguyen, Lan-Anh; Doan-Duy, Tien; Van Hoi, Bui; Vu, Cam-Tu; Le-Van, Dung; Phung-Thi, Lan-Anh; Vu-Thi, Hong-An; Chu, Dinh Binh.
  • Vu-Duc N; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Nguyen-Quang T; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Le-Minh T; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Nguyen-Thi X; Faculty of Chemistry, VNU University of Science, Vietnam National University-Hanoi, 19 Le Thanh Tong, Hanoi 100000, Vietnam.
  • Tran TM; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Vu HA; Faculty of Chemistry, VNU University of Science, Vietnam National University-Hanoi, 19 Le Thanh Tong, Hanoi 100000, Vietnam.
  • Nguyen LA; Faculty of Chemistry, VNU University of Science, Vietnam National University-Hanoi, 19 Le Thanh Tong, Hanoi 100000, Vietnam.
  • Doan-Duy T; Faculty of Chemistry, VNU University of Science, Vietnam National University-Hanoi, 19 Le Thanh Tong, Hanoi 100000, Vietnam.
  • Van Hoi B; Faculty of Chemistry, VNU University of Science, Vietnam National University-Hanoi, 19 Le Thanh Tong, Hanoi 100000, Vietnam.
  • Vu CT; Institute of Chemistry, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Le-Van D; Department of Water-Environment-Oceanography, University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Phung-Thi LA; Department of Water-Environment-Oceanography, University of Science and Technology of Hanoi (USTH), Vietnam Academy of Science and Technology (VAST), 18 Hoang Quoc Viet, Hanoi 100000, Vietnam.
  • Vu-Thi HA; Department of Chemistry, Vietnam Military Medical University, 160 Phung Hung, Hadong, Hanoi 100000, Vietnam.
  • Chu DB; School of Environmental Science and Technology, Hanoi University of Science and Technology, 1 Dai Co Viet, Hanoi 100000, Vietnam.
J Anal Methods Chem ; 2019: 3489634, 2019.
Article en En | MEDLINE | ID: mdl-31205797
ABSTRACT
An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam. Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.1% formic acid in deionized water, and methanol. The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions. These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source. The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes. The mass accuracies of target analytes were from -4.14 ppm (dinotefuran) to 1.42 ppm (cinosulfuron) in the neat solvent and from -3.91 ppm (spinosad D) to 1.29 ppm (cinosulfuron) in the matrix-matched solution. Target analytes in the vegetable-based matrix were extracted by the QuEChERS method. Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented. Excellent LOD and LOQ of the developed method were achieved at the range of 0.04-0.85 and 0.13-2.9 µg·kg-1, respectively. Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly. The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments. Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes. Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam. The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.