Your browser doesn't support javascript.
loading
Development of an effective sample transfer device for biomarker detection in nasal secretions.
Lee, Young Ju; Lee, Jae-Chul; Eun, Young Gyu; Lee, Gi-Ja.
  • Lee YJ; Dept. of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul, 02447, South Korea.
  • Lee JC; Human Convergence Technology Group, Korea Institute of Industrial Technology, Ansan, 15588, South Korea.
  • Eun YG; Dept. of Otolaryngology-Head and Neck Surgery, Kyung Hee University Medical Center, Seoul, 02447, South Korea.
  • Lee GJ; Dept. of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul, 02447, South Korea. Electronic address: gjlee@khu.ac.kr.
Anal Biochem ; 585: 113404, 2019 11 15.
Article en En | MEDLINE | ID: mdl-31445002
ABSTRACT
Nasal secretions (NS) reflect inflammatory activity of the nasal mucosa and thus can be utilized for disease diagnosis and determining treatment effects in Allergic rhinitis (AR). However, non-standardized collection of samples can affect the measured concentration of inflammatory biomarker in NS. In this study, we aimed to develop and evaluate new devices capable of standardizing the collection, storage, and preprocessing methods of NS samples. First, we chose the best swab as polyester (PE) and selected a stimulation method, twirling for 10 s at 1 Hz, to efficiently release AR biomarkers from a PE swab. Storage of sample solutions at -20 °C was optimal for the stability of biomarkers for the detection of AR. The new swab sample transfer device showed excellent concentration recovery efficiency (90-100%) for tryptase (Trp) and eosinophil cationic protein (ECP) without crosstalk between the two biomarkers. Finally, we compared the concentration of Trp in human NS samples of AR patients (n = 6) pre-processed by the new device with that by centrifuge as a standard method. As a result, the concentrations of Trp in NS were very similar in both groups. Therefore, this device can be utilized as an effective sample transfer and pre-processing device for point-of-care testing of AR.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Biomarcadores / Secreciones Corporales / Proteína Catiónica del Eosinófilo / Triptasas / Rinitis Alérgica / Mucosa Nasal Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Humans / Male Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Biomarcadores / Secreciones Corporales / Proteína Catiónica del Eosinófilo / Triptasas / Rinitis Alérgica / Mucosa Nasal Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Humans / Male Idioma: En Año: 2019 Tipo del documento: Article