Your browser doesn't support javascript.
loading
Quantum-Limited Measurements Using an Optical Cavity with Modulated Intrinsic Loss.
Tagantsev, Alexander K; Fedorov, Sergey A.
  • Tagantsev AK; Ioffe Physical-Technical Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia and Swiss Federal Institute of Technology (EPFL), School of Engineering, Institute of Materials Science, CH-1015 Lausanne, Switzerland.
  • Fedorov SA; Swiss Federal Institute of Technology (EPFL), Laboratory of Photonics and Quantum Measurements, CH-1015 Lausanne, Switzerland.
Phys Rev Lett ; 123(4): 043602, 2019 Jul 26.
Article en En | MEDLINE | ID: mdl-31491274
We analyze a cavity optomechanical setup, in which the position of an oscillator modulates the internal optical loss. We show that, in contrast to systems with a fixed internal loss, in such a setup, quantum-limited position measurements can be performed and formulate conditions under which it is possible. Additionally, under these conditions the setup exhibits a number of potential benefits for practical operation, including the complete absence of dynamical backaction and optomechanical instability, rejection of classical laser noise, and thermal fluctuations of cavity frequency from the measurement record. We address a few potential experimental implementations of this setup.

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2019 Tipo del documento: Article