Your browser doesn't support javascript.
loading
Unique Structural/Stereo-Isomer and Isobar Analysis of Novel Fentanyl Analogues in Postmortem and DUID Whole Blood by UHPLC-MS-MS.
Sofalvi, Szabolcs; Lavins, Eric S; Brooker, Ian T; Kaspar, Claire K; Kucmanic, John; Mazzola, Carrie D; Mitchell-Mata, Christie L; Clyde, Cassandra L; Rico, Rindi N; Apollonio, Luigino G; Goggin, Charissa; Marshall, Brittany; Moore, Danielle; Gilson, Thomas P.
  • Sofalvi S; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Lavins ES; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Brooker IT; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Kaspar CK; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Kucmanic J; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Mazzola CD; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Mitchell-Mata CL; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Clyde CL; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Rico RN; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Apollonio LG; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
  • Goggin C; Phenomenex®, 411 Madrid Avenue, Torrance, CA 90501, USA.
  • Marshall B; Phenomenex®, 411 Madrid Avenue, Torrance, CA 90501, USA.
  • Moore D; Phenomenex®, 411 Madrid Avenue, Torrance, CA 90501, USA.
  • Gilson TP; Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
J Anal Toxicol ; 43(9): 673-687, 2019 Oct 17.
Article en En | MEDLINE | ID: mdl-31504606
ABSTRACT
The presented analytical method enabled the Toxicology Department at the Cuyahoga County Medical Examiner's Office to identify 26 and quantitatively report 24 compounds in 500 µL of whole blood, including fentanyl analogues (fentalogues) such as methoxyacetyl fentanyl (MeOAF) and cyclopropyl fentanyl (CPF). This second-generation method (FG2) was developed with the objective to improve the existing analysis (FG1) by decreasing sample size, lowering limits of detection (LOD) and lower limit of quantitation, minimizing ion suppression and resolving chromatographic interferences. Interferences may occur in the analysis of fentanyl, MeOAF, CPF, 3-methylfentanyl (3MF), butyryl fentanyl and isobutyryl fentanyl due to isobars and structural or geometric isomerism with another analogue or metabolite. The isomeric and isobaric fentalogues were grouped into three sets. The LOD established for Set 1 [MeOAF, para-methoxyacetyl fentanyl, para-fluoro acryl fentanyl (isobar), fentanyl carbamate], 2-furanyl fentanyl, Set 2 [CPF, (E)-crotonyl fentanyl] and carfentanil was 0.0125 ng/mL. The LOD established for N-methyl norfentanyl, norfentanyl, norcarfentanil, despropionyl fentanyl (4-ANPP), acetyl fentanyl, ß-hydroxy fentanyl, benzyl fentanyl, acryl fentanyl, alfentanil, fentanyl, para-fluoro fentanyl, Set 3 [(±)-trans-3MF, (±)-cis-3MF, isobutyryl and butyryl fentanyl], para-fluoroisobutyryl fentanyl, sufentanil, phenyl fentanyl and cyclopentenyl fentanyl was 0.0625 ng/mL. Seven-point linear calibration curves were established between 0.025 and 4.0 ng/mL for the 8 analytes with the lower LOD and 0.125 and 20 ng/mL for the 18 analytes with the higher LOD. 4-ANPP and cyclopentenyl fentanyl met qualitative reporting criteria only. The results for five postmortem and two driving under the influence of drugs authentic case samples are presented. To the authors' knowledge, FG2 is the first published method that achieved baseline resolution of the nine structural/stereo isomers and one isobar by ultra-high performance liquid chromatography-MS-MS and provided quantitative validation data for nine compounds. FG2 may be used as the new baseline for future isomers that need to be chromatographically separated.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fentanilo / Analgésicos Opioides Tipo de estudio: Prognostic_studies / Qualitative_research Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fentanilo / Analgésicos Opioides Tipo de estudio: Prognostic_studies / Qualitative_research Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article