Your browser doesn't support javascript.
loading
Benefit of including CT urography in [68Ga]PSMA-11 PET/CT with low-dose CT: first results from a larger prostate cancer cohort analysis.
Rosar, Florian; Hügle, Martin J; Ries, Martin; Bartholomä, Mark; Maus, Stephan; Fries, Peter; Khreish, Fadi; Ezziddin, Samer.
  • Rosar F; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany - florian.rosar@uks.eu.
  • Hügle MJ; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
  • Ries M; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
  • Bartholomä M; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
  • Maus S; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
  • Fries P; Clinic of Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg, Germany.
  • Khreish F; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
  • Ezziddin S; Department of Nuclear Medicine, Saarland University Medical Center, Homburg, Germany.
Q J Nucl Med Mol Imaging ; 66(3): 280-289, 2022 Sep.
Article en En | MEDLINE | ID: mdl-31992688
ABSTRACT

BACKGROUND:

Accuracy of [68Ga]PSMA-11 PET/CT may be hampered by ureter accumulation, mimicking lymph node metastases depending on localization and configuration. The benefit of CT urography for differentiation of lymph node metastasis from urinary tract activity was evaluated in a "PET/CT with low-dose CT" setting.

METHODS:

Retrospective analysis of PET/CT for primary staging, biochemical recurrence or local treatment planning in patients with prostate cancer. For CT urography (CTU), iodinated contrast agent was administered 10 minutes prior to image acquisition. All potential pathologic (peri)ureteral tracer uptake was assigned to excretory ureteral accumulation or pathological lesion. To assess additional provided benefit of CTU all foci were rated with an introduced scoring system (ranging from 0 pts CTU not needed; up to 3 pts no differentiation possible without CTU). Success of ureter contrasting was assessed by measurement of Hounsfield units. Besides benefit for reading urography-enhanced PET/CT, the possible impact on subsequent patient treatment was evaluated.

RESULTS:

A number of N.=247 patients were included in this study. By CT urography, it was possible to identify each ureter on low-dose CT, with its major part contrasted. In 120/247 (48.6%) patients, urography increased the diagnostic confidence while providing substantial support for interpretation in 60 (24.3%) cases. In 42 (17.0%) patients, urography was clinically relevant (up-/downstaging) with potential impact on subsequent patient care. In 30 of these 42 cases (12.1% of all), discrepant treatment would have resulted from a misdiagnosed tracer accumulation without urography.

CONCLUSIONS:

CT urography benefits the interpretation of [68Ga]-PSMA-11 PET/CT with low-dose CT and leads to discrepant patient treatment in a small but significant subset of patients (12% in our cohort). The implementation of CT urography into standard protocols of [68Ga]PSMA-11 PET/CT with low-dose CT is recommended.