Your browser doesn't support javascript.
loading
Beam and installation improvements of the NIO1 ion source.
Cavenago, M; Barbisan, M; Delogu, R; Pimazzoni, A; Poggi, C; Ugoletti, M; Agostini, M; Antoni, V; Baltador, C; Cervaro, V; De Muri, M; Giora, D; Jain, P; Laterza, B; Maero, G; Maniero, M; Martini, D; Minarello, A; Ravarotto, D; Recchia, D; Rizzolo, A; Romé, M; Sartori, E; Sattin, M; Serianni, G; Taccogna, F; Valentino, V; Variale, V; Veltri, P.
  • Cavenago M; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Barbisan M; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Delogu R; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Pimazzoni A; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Poggi C; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Ugoletti M; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Agostini M; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Antoni V; CNR-Istituto Scienza e Tecnologia dei Plasmi, c. Stati Uniti 4, 35127 Padova, Italy.
  • Baltador C; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Cervaro V; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • De Muri M; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Giora D; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Jain P; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Laterza B; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Maero G; Univ. Milano and INFN-MI, v. Celoria 16, 20133 Milano, Italy.
  • Maniero M; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Martini D; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Minarello A; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Ravarotto D; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Recchia D; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Rizzolo A; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Romé M; Univ. Milano and INFN-MI, v. Celoria 16, 20133 Milano, Italy.
  • Sartori E; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Sattin M; INFN-LNL, v.le dell'Universitá 2, 35020 Legnaro (PD), Italy.
  • Serianni G; Consorzio RFX, c. Stati Uniti 4, 35127 Padova, Italy.
  • Taccogna F; CNR-Istituto Scienza e Tecnologia dei Plasmi, c. Stati Uniti 4, 35127 Padova, Italy.
  • Valentino V; INFN-BA, v. Orabona 4, 70126 Bari, Italy.
  • Variale V; INFN-BA, v. Orabona 4, 70126 Bari, Italy.
  • Veltri P; ITER-Organization, 13067 St. Paul Lez Durance Cedex, France.
Rev Sci Instrum ; 91(1): 013316, 2020 Jan 01.
Article en En | MEDLINE | ID: mdl-32012575
ABSTRACT
The NIO1 (Negative Ion Optimization phase 1) source can provide continuous beam operation, which is convenient for systematic parameter and equipment studies. Even in the pure volume production regime, the source yield was found to depend on conditioning procedures. Magnetic configuration tests continued adding magnets to the existing setup; the filter field component Bx has been progressively extended to span the -12 to 5 mT range, and as a trend, source performances improved with |Bx|. The progress of camera beam diagnostics and of the quality of the volume-produced H- beam is also shown. The status, off-line results, and reliability of a first NIO1 cesium oven are discussed; other upgrades in preparation (cavity ring down spectrometer, the end calorimeter, and conceptual tests of the energy recovery system) are also listed.

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2020 Tipo del documento: Article