Inability to capture with increasing current strength: Is this near-field or far-field?
Liu, Fang-Zhou; Liao, Hong-Tao; Zhan, Xian-Zhang; Shehata, Michael; Ehdaie, Ashkan; Chen, Qiu-Fan; Wu, Shu-Lin; Xue, Yu-Mei; Wang, Xun-Zhang.
  • Liu FZ; Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
  • Liao HT; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California.
  • Zhan XZ; Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
  • Shehata M; Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
  • Ehdaie A; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California.
  • Chen QF; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California.
  • Wu SL; Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
  • Xue YM; Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
  • Wang XZ; Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
J Cardiovasc Electrophysiol ; 31(4): 960-963, 2020 04.
Article en En | MEDLINE | ID: mdl-32077548
ABSTRACT
We present a case of wide-complex tachycardia in which the clinical electrophysiological diagnosis was considered to be bundle branch re-entry ventricular tachycardia. A series of ventricular entrainment attempts were performed from the left and right ventricular septum to confirm the diagnosis. Entrainment pacing with a general current output (10 mA) was performed from the right ventricular septum with manifest fusion and a post-pacing interval similar to tachycardia cycle length. Thereafter, another entrainment attempt with a greater current output (20 mA) was performed from the same site. Paradoxically, concealed fusion was demonstrated by selective RB capture only, though there was no clear "RB" potential seen. In this case, we attempt to explain and illustrate the mechanism of paradoxical near-field inability to capture with increasing current strength.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fascículo Atrioventricular / Potenciales de Acción / Estimulación Cardíaca Artificial / Taquicardia Ventricular / Técnicas Electrofisiológicas Cardíacas / Electrocardiografía / Frecuencia Cardíaca Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fascículo Atrioventricular / Potenciales de Acción / Estimulación Cardíaca Artificial / Taquicardia Ventricular / Técnicas Electrofisiológicas Cardíacas / Electrocardiografía / Frecuencia Cardíaca Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans Idioma: En Año: 2020 Tipo del documento: Article