Your browser doesn't support javascript.
loading
Measurement of inotropy and systemic oxygen delivery in term, low- and very-low-birth-weight neonates using the Ultrasonic Cardiac Output Monitor (USCOM).
Zheng, Man-Li; He, Shao-Ru; Liu, Yu-Mei; Chen, Lin.
  • Zheng ML; The Second School of Clinical Medicine, Southern Medical University, Guangzhou, P.R. China.
  • He SR; Department of Pediatrics, Guangdong Academy of Medical Sciences, Guangdong Provincial People's Hospital, Guangzhou, P.R. China.
  • Liu YM; The Second School of Clinical Medicine, Southern Medical University, Guangzhou, P.R. China.
  • Chen L; Department of Pediatrics, Guangdong Academy of Medical Sciences, Guangdong Provincial People's Hospital, Guangzhou, P.R. China.
J Perinat Med ; 48(3): 289-295, 2020 Mar 26.
Article en En | MEDLINE | ID: mdl-32083449
ABSTRACT
Background The aim of this study was to assess the normal values of the Smith-Madigan inotropy index (SMII) and oxygen delivery index (DO2I) in low-birth-weight (LBW) and very-low-birth-weight (VLBW) newborns on the first 3 days of life, and to identify how different degrees of maturity influence cardiovascular alterations during the transitional period compared with term neonates. Methods Twenty-eight VLBW newborns, 46 LBW newborns and 50 normal full-term newborns admitted to our department were studied. Hemodynamics of the left heart were measured in all neonates over the first 3 days using the Ultrasonic Cardiac Output Monitor (USCOM). This was combined with hemoglobin concentration and pulse oximetry to calculate DO2I. Blood pressure was combined with the hemodynamic measures and hemoglobin concentration to calculate SMII. Results SMII showed statistically significant differences among the three groups (VLBW 0.48 ± 0.11; LBW 0.54 ± 0.13; term 0.69 ± 0.17 W/m2 P < 0.001), which was in line with the following myocardial parameters stroke volume index (SVI) and cardiac index (CI) (P < 0.001 and <0.001). For systemic oxygen delivery (DO2) parameters, significant differences were found for DO2I (P < 0.001) while hemoglobin concentration and pulse oximetry demonstrated no significant differences. In the VLBW group, SMII and DO2I showed no significant change over the 3 days. Conclusion Normal inotropy and systemic DO2I values in VLBW neonates over the first 3 days of life were assessed. SMII and DO2I were significantly lower in VLBW neonates during the first 72 h of life. With increasing birth weight, higher myocardial inotropy and DO2 were found. The addition of USCOM examination to standard neonatal echocardiography may provide further important information regarding cardiac function.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Recién Nacido de Bajo Peso / Gasto Cardíaco Tipo de estudio: Observational_studies Límite: Female / Humans / Male / Newborn Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Recién Nacido de Bajo Peso / Gasto Cardíaco Tipo de estudio: Observational_studies Límite: Female / Humans / Male / Newborn Idioma: En Año: 2020 Tipo del documento: Article