Your browser doesn't support javascript.
loading
[Pathophysiological Study on Thoracic Ascending Aorta of Mice with Myh11 R247C Heterozygous Mutation in Norepinephrine-induced Hypertension Model].
Yang, Yun; Wu, Zhou-Peng; Shu, Ye; Sweeney, H Lee; Huang, Bin.
  • Yang Y; Department of Gastrointestinal Surgery, Chengdu Shang Jin Nan Fu Hospital, West China Hospital​​​​​​​, Sichuan University, Chengdu 611743, China.
  • Wu ZP; Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Shu Y; Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, Chengdu 610041, China.
  • Sweeney HL; Department of Pharmacology and Therapeutics, University of Florida College of Medicine, Gainesville, FL Myology Institute, University of Florida College of Medicine, Gainesville FL32653, USA.
  • Huang B; Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu 610041, China.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 51(2): 200-206, 2020 Mar.
Article en Zh | MEDLINE | ID: mdl-32220188
ABSTRACT
OBJEVTIVE To explore the thoracic ascending aortic (TAA) pathophysiological characteristics of heterozygous mutant Myh11 R247C/+ mice under the norepinephrine-induced hypertension mode.

METHODS:

Female heterozygous mutant Myh11 R247C/+ and wild type Myh11 +/+ mice were selected as experimental group (HET group) and control group (WT group),respectively. The hypertensive model was induced by intraperitoneal injection of norepinephrine (NE),and TAA diameter and invasive blood pressure (Bp) data were collected dynamically in real time using high-frequency ultrasound imaging and invasive arterial blood pressure monitoring technique,so as to indirectly analyze TAA compliance of two groups of mice. At the same time,the incidences of hemothorax and TAA rupture were further analyzed by autopsy and histology.

RESULTS:

After injection of NE,heterozygous mice did not show a higher Bp increase percentage in systole or diastole comparing with wildtype mice. However,heterozygous mice exhibited 17% and 32% higher TAA diameter dilation percentage than wildtype ones in systole and diastole respectively. Two heterozygous mice had TAA dissection and rupture,and the incidence of hemothorax in heterozygous mice (3/5) was higher than that in wildtype (0/5).

CONCLUSION:

It was very likely that the altered TAA wall compliance of mutant Myh11 R247C/+ mice had led to a higher TAA dilation degree than that in wildtype,and even could be the potential reason of TAA dissection and rupture.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aorta Torácica / Aneurisma de la Aorta Torácica / Aneurisma Roto / Cadenas Pesadas de Miosina / Hipertensión Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aorta Torácica / Aneurisma de la Aorta Torácica / Aneurisma Roto / Cadenas Pesadas de Miosina / Hipertensión Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Año: 2020 Tipo del documento: Article