Your browser doesn't support javascript.
loading
Rapid toxicity assessment of six antifouling booster biocides using a microplate-based chlorophyll fluorescence in Undaria pinnatifida gametophytes.
Lee, Hojun; Depuydt, Stephen; Choi, Soyeon; Han, Taejun; Park, Jihae.
  • Lee H; Department of Marine Science, Incheon National University, 119, Academy-ro, Yeonsu-gu, Incheon, 22012, Republic of Korea.
  • Depuydt S; Ghent University Global Campus, 119-5, Songdomunhwa-ro, Yeonsu-gu, Incheon, 21985, Republic of Korea.
  • Choi S; Ghent University Global Campus, 119-5, Songdomunhwa-ro, Yeonsu-gu, Incheon, 21985, Republic of Korea.
  • Han T; Department of Marine Science, Incheon National University, 119, Academy-ro, Yeonsu-gu, Incheon, 22012, Republic of Korea.
  • Park J; Department of Marine Science, Incheon National University, 119, Academy-ro, Yeonsu-gu, Incheon, 22012, Republic of Korea.
Ecotoxicology ; 29(5): 559-570, 2020 Jul.
Article en En | MEDLINE | ID: mdl-32333251
ABSTRACT
Biocides of antifouling agents can cause problems in marine ecosystems by damaging to non-target algal species. Aquatic bioassays are important means of assessing the quality of water containing mixtures of contaminants and of providing a safety standard for water management in an ecological context. In this study, a rapid, sensitive and inexpensive test method was developed using free-living male and female gametophytes of the brown macroalga Undaria pinnatifida. A conventional fluorometer was employed to evaluate the acute (48 h) toxic effects of six antifouling biocides 4,5-Dichloro-2-octyl-isothiazolone (DCOIT), diuron, irgarol, medetomidine, tolylfluanid, zinc pyrithione (ZnPT). The decreasing toxicity in male and female gametophytes as estimated by EC50 (effective concentration at which 50% inhibition occurs) values was diuron (0.037 and 0.128 mg l-1, respectively) > irgarol (0.096 and 0.172 mg l-1, respectively) > tolylfluanid (0.238 and 1.028 mg l-1, respectively) > DCOIT (1.015 and 0.890 mg l-1, respectively) > medetomidine (12.032 and 12.763 mg l-1, respectively). For ZnPT, 50% fluorescence inhibition of U. pinnatifida gametophytes occurred at concentrations above 0.4 mg l-1. The Undaria method is rapid, simple, practical, and cost-effective for the detection of photosynthesis-inhibiting biocides, thus making a useful tool for testing the toxicity of antifouling agents in marine environments.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pruebas de Toxicidad / Undaria / Desinfectantes Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pruebas de Toxicidad / Undaria / Desinfectantes Idioma: En Año: 2020 Tipo del documento: Article