Your browser doesn't support javascript.
loading
Analysis of Corneal Densitometry and Endothelial Cell Function in Fuchs Uveitis Syndrome.
Simsek, Mert; Cakar Ozdal, Pinar; Cankurtaran, Mahmut; Ozdemir, Huseyin Baran; Elgin, Ufuk.
  • Simsek M; Department of Ophthalmology (M.S., P.C.O., M.C., U.E.), University of Health Sciences, Ulucanlar Eye Education and Research Hospital, Ankara, Turkey ; and Department of Ophthalmology (H.B.O.), Gazi University School of Medicine, Ankara, Turkey .
Eye Contact Lens ; 47(4): 196-202, 2021 Apr 01.
Article en En | MEDLINE | ID: mdl-32483051
ABSTRACT

OBJECTIVES:

To evaluate corneal densitometry and endothelial cell properties in patients with unilateral Fuchs uveitis syndrome (FUS), and to compare results with unaffected contralateral eyes and healthy control subjects.

METHODS:

A total of 90 participants were included in this prospective cross-sectional study. Forty-five affected eyes of patients with FUS were regarded as group 1 (FUSa), 45 fellow eyes were regarded as group 2 (FUSf), and 45 healthy-control eyes were regarded as group 3. Corneal densitometry was measured with densitometry software of Scheimpflug Corneal Topography (Pentacam HR, Oculus GmbH, Wetzlar, Germany), whereas endothelial cell measurement was evaluated with specular microscopy (Tomey, EM4000, GmbH, Germany).

RESULTS:

The mean corneal densitometry values were higher in the midstromal (zones; 2-6, 6-10 mm), posterior (all zones), and total thickness (zones; 2-6, 6-10 mm) layers in the FUSa compared with FUSf and control eyes (P<0.05 for all comparisons). The mean values of average cell area and cell size characteristics (minimum, maximum, SD, and coefficient of variation) were higher; endothelial cell density and percentage of hexagonal cells were lower in the FUSa than in the other two groups (P<0.05 for all comparisons). There was a significantly strong correlation between specular microscopy parameters and posterior corneal densitometry values in the FUSa group.

CONCLUSIONS:

Impairment of endothelial cell function in affected eyes of patients with FUS resulted in increased values of corneal densitometry, especially posterior layer.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Uveítis / Córnea Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Uveítis / Córnea Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article