Your browser doesn't support javascript.
loading
Simultaneous assay of segesterone acetate (Nestorone®), estradiol, progesterone, and estrone in human serum by LC-MS/MS.
Erikson, David W; Blue, Steven W; Fecteau, Kristopher M; Edelman, Alison B; Jensen, Jeffrey T; Blithe, Diana L.
  • Erikson DW; Endocrine Technologies Core, Oregon National Primate Research Center, Beaverton, OR, United States. Electronic address: erikson@ohsu.edu.
  • Blue SW; Endocrine Technologies Core, Oregon National Primate Research Center, Beaverton, OR, United States.
  • Fecteau KM; Endocrine Technologies Core, Oregon National Primate Research Center, Beaverton, OR, United States.
  • Edelman AB; Department of Obstetrics & Gynecology, Oregon Health & Science University, Portland, OR, United States.
  • Jensen JT; Department of Obstetrics & Gynecology, Oregon Health & Science University, Portland, OR, United States.
  • Blithe DL; Contraceptive Development Program, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, United States.
Contraception ; 102(5): 361-367, 2020 11.
Article en En | MEDLINE | ID: mdl-32828731
ABSTRACT

OBJECTIVE:

To develop a method to simultaneously quantify the synthetic contraceptive progestin segesterone acetate (Nestorone®, NES) and the endogenous steroid hormones estradiol (E2), progesterone (P4), and estrone (E1) in human serum samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). STUDY

DESIGN:

We analyzed 615 serum samples collected from 67 reproductive-age women actively using a contraceptive vaginal ring (CVR) designed to release NES (200 mcg/d) and E2 (75-200 mcg/d). Samples were taken prior to and up to 30 days after CVR insertion and analyzed for concentrations of NES, E2, P4, and E1 in human serum using a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. Precision, accuracy, and sensitivity for all analytes were determined across multiple assays.

RESULTS:

The assay ranges for NES, E2, P4, and E1 in this analytical method were 10 pg/mL to 10 ng/mL with a lower limit of quantification of 10 pg/mL for all targets. Assay precisions were less than or equal to 14.5% and accuracies ranged from 87.0% to 110.8%. When applied to the 615 clinical samples, 550 samples had quantifiable concentrations of NES (value range 0.014-1471 ng/mL). Similarly, 595 samples had quantifiable concentrations of E2 (0.010-0.312 ng/mL), 596 samples had quantifiable concentrations of P4 (0.010-5.791 ng/mL), and 609 samples had quantifiable concentrations of E1 (0.010-0.416 ng/mL).

CONCLUSIONS:

The LC-MS/MS platform results in a robust, accurate, and sensitive method for the simultaneous quantification of NES and endogenous steroid hormones in human serum. IMPLICATIONS The analytical method described allows for the simultaneous quantification of NES and endogenous steroids and can be used to monitor NES concentrations during clinical trials and subject adherence to treatment with NES.