Your browser doesn't support javascript.
loading
Extravascular Lung Water and Effect on Oxygenation Assessed by Lung Ultrasound in Adult Cardiac Surgery.
Emperador, Francis; Bennett, Sean R; Gonzalez, Julia; Saati, Ahmed; Alsaywid, Basim S; Fernandez, Jose A.
  • Emperador F; Critical Care, Great Ormond Street Hospital, London, GBR.
  • Bennett SR; King Faisal Cardiac Center, Cardiac Anesthesiology, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Jeddah, SAU.
  • Gonzalez J; King Faisal Cardiac Center, Cardiac Anesthesiology, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Jeddah, SAU.
  • Saati A; Department of Surgery, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Jeddah, SAU.
  • Alsaywid BS; Department of Surgery, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Jeddah, SAU.
  • Fernandez JA; Research and Development Department, Clinical Epidemiology, King Abdulaziz University Hospital, Riyadh, SAU.
Cureus ; 12(8): e9953, 2020 Aug 23.
Article en En | MEDLINE | ID: mdl-32983659
ABSTRACT
Introduction The extravascular lung water content is determined by the use of lung ultrasound (LUS) which is represented as B-lines. The aim of this study was to investigate whether the LUS measurement of extravascular lung water was correlated to changes in oxygenation. Methods This prospective cohort study was comprised of 73 patients with an average age of 56 (range 18 to 87 years) who underwent elective cardiac surgery using cardiopulmonary bypass. The LUS score was performed preoperatively, time zero (T0), at one hour (T1), and at 24 hours (T2) post-surgery. Additionally, arterial oxygen partial pressure and fraction of inspired oxygen (PaO2/FiO2) ratio were measured at each time and the time-to-extubation. Results A negative correlation was found between the LUS score and PaO2/FiO2 at T1 (p < 0.004). Extubation time and changes in the lung ultrasound score at T0 - T2 were positively correlated (p < 0.03). Plus, there was a positive correlation between fluid balance and lung ultrasound score at T2 (p < 0.03). Conclusion We found three significant correlations that support the use of LUS in cardiac surgery 1) the more B-lines, the lower the oxygenation; 2) the more B-lines, the longer the period of ventilation; 3) the more B-lines, the more positive the fluid balance. LUS is a non-invasive bedside investigation that can be used to judge extravascular lung water, providing useful information in the management of patient oxygenation, fluid balance, and extubation.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Observational_studies Idioma: En Año: 2020 Tipo del documento: Article