Your browser doesn't support javascript.
loading
Determination of dexamethasone acetate in CETETH 20-based in liquid crystalline systems using HPLC.
Oyafuso, Márcia Helena; Fonseca-Santos, Bruno; Kogawa, Ana Carolina; Carvalho, Flávia Chiva; Gremião, Maria Palmira Daflon; Chorilli, Marlus.
  • Oyafuso MH; Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil.
  • Fonseca-Santos B; Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil.
  • Kogawa AC; Laboratório de Controle de Qualidade, Faculdade de Farmácia, Universidade Federal de Goiás-UFG, Goiânia, Goiás, Brazil.
  • Carvalho FC; Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil.
  • Gremião MPD; Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil.
  • Chorilli M; Department of Drugs and Medicines, School of Pharmaceutical Sciences, São Paulo State University (UNESP), Araraquara, SP, Brazil.
Biomed Chromatogr ; 35(5): e5054, 2021 May.
Article en En | MEDLINE | ID: mdl-33314174
Dexamethasone acetate (DEX), a potent anti-inflammatory, is used primarily in the treatment of inflammatory and autoimmune diseases. It was incorporated in CETETH 20 (polyoxyethylene 20 cetyl alcohol)-based liquid crystalline systems to enhance the purpose of the drug. Concomitant with the pharmaceutical technology performed, a HPLC method was developed and validated for the quantification of dexamethasone acetate in CETETH 20-based liquid crystalline systems for the evaluation of the drug in the new matrix. The method was performed using a C18 column with acetonitrile:methanol:water (35:35:30, v/v/v) as the mobile phase at a flow rate of 0.8 mL min-1 at 239 nm. The method was linear in the range of 1-25 µg mL-1 ; the limit of quantification and limit of detection were 0.05 and 0.16 µg mL-1 , respectively; the accuracy of the method was 99.92% (relative standard deviation < 1%), and it presented intra-day and inter-day precision with deviations less than 1%. In this context, the method was successfully used to determine the incorporation efficiency of DEX in CETETH 20-based liquid crystalline systems and can be easily used by pharmaceutical companies and laboratories around the world.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dexametasona / Cromatografía Líquida de Alta Presión / Cristales Líquidos / Antiinflamatorios Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dexametasona / Cromatografía Líquida de Alta Presión / Cristales Líquidos / Antiinflamatorios Idioma: En Año: 2021 Tipo del documento: Article