Your browser doesn't support javascript.
loading
Locking versus non-locking plating system in the treatment of mandibular fractures: A randomized comparative study.
Sarkar, Dibya Falgoon; Mishra, Niranjan; Samal, Dipti; Pati, Debashish; Kar, Indu Bhusan; Mohapatra, Debjyoti; Mishra, Abhipsa.
  • Sarkar DF; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: falgoon.sarkar@gmail.com.
  • Mishra N; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: drniranjanmishra@gmail.com.
  • Samal D; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: diptisamal87@gmail.com.
  • Pati D; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: debashish.pati@outlook.com.
  • Kar IB; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: indubkar@gmail.com.
  • Mohapatra D; Department of Community Medicine, S.C.B. Medical College and Hospital, Cuttack, Odisha, India. Electronic address: drdebjyoti@gmail.com.
  • Mishra A; Department of Oral and Maxillofacial Surgery, S.C.B. Dental College and Hospital, Cuttack, Odisha, India. Electronic address: abhipsa13.rkl@gmail.com.
J Craniomaxillofac Surg ; 49(3): 184-190, 2021 Mar.
Article en En | MEDLINE | ID: mdl-33516587
ABSTRACT
To evaluate fracture stability and complications such as infections, need for hardware removal, malunion, and nonunion when using 2.0-mm locking plating system in fixation of mandible fractures and to compare these to those associated with the 2.0-mm non-locking plating system. A prospective clinical study was conducted in a cohort of mandible fracture patients who were randomly assigned to two groups. Patients in the non-locking group were treated with 2.0-mm non-locking plating system, and those in locking group were treated with 2.0-mm locking plating system. Fracture stability, need for maxillomandibular fixation (MMF) and postoperative complications were assessed and compared. A total of 60 patients (30 in each group) were recruited. Significant differences were found between the two groups with respect to postoperative fracture stability (P = 0.001) and need for MMF (P = 0.005). Multivariate analysis revealed that type of fixation was not the only dependent variable which affected fracture stability. There were no significant differences in postoperative complications between the two groups. The 2.0-mm locking plating system provides greater stability and early functional restoration than the 2.0-mm non-locking plating system, with similar rates of postoperative complications. Thus, it can be used as a reliable and effective treatment modality for treating mandibular fractures.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantes Dentales / Fracturas Mandibulares Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantes Dentales / Fracturas Mandibulares Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article