Electrocardiogram-less, free-breathing myocardial extracellular volume fraction mapping in small animals at high heart rates using motion-resolved cardiovascular magnetic reesonance multitasking: a feasibility study in a heart failure with preserved ejection fraction rat model.
Han, Pei; Zhang, Rui; Wagner, Shawn; Xie, Yibin; Cingolani, Eugenio; Marban, Eduardo; Christodoulou, Anthony G; Li, Debiao.
  • Han P; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Zhang R; Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA.
  • Wagner S; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Xie Y; Department of Cardiology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Cingolani E; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Marban E; Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Christodoulou AG; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Li D; Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
J Cardiovasc Magn Reson ; 23(1): 8, 2021 02 11.
Article en En | MEDLINE | ID: mdl-33568177
BACKGROUND: Extracellular volume fraction (ECV) quantification with cardiovascular magnetic resonance (CMR) T1 mapping is a powerful tool for the characterization of focal or diffuse myocardial fibrosis. However, it is technically challenging to acquire high-quality T1 and ECV maps in small animals for preclinical research because of high heart rates and high respiration rates. In this work, we developed an electrocardiogram (ECG)-less, free-breathing ECV mapping method using motion-resolved CMR Multitasking on a 9.4 T small animal CMR system. The feasibility of characterizing diffuse myocardial fibrosis was tested in a rat heart failure model with preserved ejection fraction (HFpEF). METHODS: High-salt fed rats diagnosed with HFpEF (n = 9) and control rats (n = 9) were imaged with the proposed ECV Multitasking technique. A 25-min exam, including two 4-min T1 Multitasking scans before and after gadolinium injection, were performed on each rat. It allows a cardiac temporal resolution of 20 ms for a heart rate of ~ 300 bpm. Myocardial ECV was calculated from the hematocrit (HCT) and fitted T1 values of the myocardium and the blood pool. Masson's trichrome stain was used to measure the extent of fibrosis. Welch's t-test was performed between control and HFpEF groups. RESULTS: ECV was significantly higher in the HFpEF group (22.4% ± 2.5% vs. 18.0% ± 2.1%, P = 0.0010). A moderate correlation between the ECV and the extent of fibrosis was found (R = 0.59, P = 0.0098). CONCLUSIONS: Motion-resolved ECV Multitasking CMR can quantify ECV in the rat myocardium at high heart rates without ECG triggering or respiratory gating. Elevated ECV found in the HFpEF group is consistent with previous human studies and well correlated with histological data. This technique has the potential to be a viable imaging tool for myocardial tissue characterization in small animal models.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Respiración / Volumen Sistólico / Imagen por Resonancia Magnética / Función Ventricular Izquierda / Técnicas de Imagen Sincronizada Cardíacas / Insuficiencia Cardíaca / Frecuencia Cardíaca Tipo de estudio: Etiology_studies / Prognostic_studies Límite: Animals Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Respiración / Volumen Sistólico / Imagen por Resonancia Magnética / Función Ventricular Izquierda / Técnicas de Imagen Sincronizada Cardíacas / Insuficiencia Cardíaca / Frecuencia Cardíaca Tipo de estudio: Etiology_studies / Prognostic_studies Límite: Animals Idioma: En Año: 2021 Tipo del documento: Article