Investigation of corneal topographic and densitometric properties of Wilson's disease patients with or without a Kayser-Fleischer ring.
Alakus, Mehmet Fuat; Caglayan, Mehtap; Ekin, Nazim; Oncul, Hasan; Arac, Esref; Dag, Umut; Diri, Halit.
  • Alakus MF; Department of Ophthalmology, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey. fuat2112@hotmail.com.
  • Caglayan M; Department of Ophthalmology, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
  • Ekin N; Department of Internal Medicine, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
  • Oncul H; Department of Ophthalmology, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
  • Arac E; Department of Internal Medicine, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
  • Dag U; Department of Ophthalmology, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
  • Diri H; Department of Internal Medicine, University of Health Sciences, Diyarbakir Gazi Yasargil Research and Training Hospital, Diyarbakir, Turkey.
Eye Vis (Lond) ; 8(1): 8, 2021 Mar 11.
Article en En | MEDLINE | ID: mdl-33706814
ABSTRACT

BACKGROUND:

To investigate the topographic measurements and densitometry of corneas in Wilson's disease (WD) patients with or without a Kayser-Fleischer ring (KF-r) compared to healthy individuals.

METHODS:

This cross-sectional study included 20 WD patients without a KF-r (group I), 18 WD patients with a KF-r (group II), and 20 age-matched controls (group III). The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.

RESULTS:

Mean age for groups I, II and III was 25.40 ± 6.43 years (14-36 years), 25.38 ± 6.96 years (16-39 years), 23.60 ± 6.56 years (17-35 years), respectively (P = 0.623). There was no significant difference between the groups in terms of the anterior corneal densitometry values (P > 0.05), while the 6-10 mm and 10-12 mm mid stroma and the 2-6 mm, 6-10 mm, and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III (for all values, P <  0.05). However, the 10-12 mm posterior corneal densitometry values in group I were also significantly higher than those in group III (P = 0.038). The central corneal thickness (CCT), thinnest corneal thickness (tCT), and corneal volume (CV) values in groups I and II were significantly lower than those in group III (for CCT values, P = 0.011 and P = 0.009; for tCT values, P = 0.010 and P = 0.005; for CV values, P = 0.043 and P = 0.029).

CONCLUSION:

In WD patients with a KF-r, corneal transparency decreased in the peripheral posterior and mid stromal corneal layers; for these patients, corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.