Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE.
Zradzinski, Patryk; Karpowicz, Jolanta; Gryz, Krzysztof; Owczarek, Grzegorz; Ramos, Victoria.
  • Zradzinski P; Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, Poland.
  • Karpowicz J; Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, Poland.
  • Gryz K; Laboratory of Electromagnetic Hazards, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, Poland.
  • Owczarek G; Eye and Face Protection Laboratory, Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Czerniakowska 16, 00-701 Warszawa, Poland.
  • Ramos V; Telemedicine and e-Health Research Unit, Instituto de Salud Carlos III, Avda. Monforte de Lemos, 5, 28029 Madrid, Spain.
Sensors (Basel) ; 21(12)2021 Jun 21.
Article en En | MEDLINE | ID: mdl-34205808
ABSTRACT
The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865-868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dispositivo de Identificación por Radiofrecuencia / Equipo de Protección Personal Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dispositivo de Identificación por Radiofrecuencia / Equipo de Protección Personal Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article