Your browser doesn't support javascript.
loading
Automated cardiac volume assessment and cardiac long- and short-axis imaging plane prediction from electrocardiogram-gated computed tomography volumes enabled by deep learning.
Chen, Zhennong; Rigolli, Marzia; Vigneault, Davis Marc; Kligerman, Seth; Hahn, Lewis; Narezkina, Anna; Craine, Amanda; Lowe, Katherine; Contijoch, Francisco.
  • Chen Z; Department of Bioengineering, UC San Diego School of Engineering, 9500 Gilman Drive, MC 0412, La Jolla, CA 92093, USA.
  • Rigolli M; Department of Bioengineering, UC San Diego School of Engineering, 9500 Gilman Drive, MC 0412, La Jolla, CA 92093, USA.
  • Vigneault DM; Department of Internal Medicine, Scripps Mercy Hospital, 4077 Fifth Ave, San Diego, CA 92103, USA.
  • Kligerman S; Department of Radiology, UC San Diego School of Medicine, 9500 Gilman Drive, La Jolla, CA 92093, USA.
  • Hahn L; Department of Radiology, UC San Diego School of Medicine, 9500 Gilman Drive, La Jolla, CA 92093, USA.
  • Narezkina A; Department of Medicine, Division of Cardiology, UC San Diego School of Medicine, 9500 Gilman Dr, La Jolla, CA 92093, USA.
  • Craine A; Department of Bioengineering, UC San Diego School of Engineering, 9500 Gilman Drive, MC 0412, La Jolla, CA 92093, USA.
  • Lowe K; Department of Bioengineering, UC San Diego School of Engineering, 9500 Gilman Drive, MC 0412, La Jolla, CA 92093, USA.
  • Contijoch F; Department of Bioengineering, UC San Diego School of Engineering, 9500 Gilman Drive, MC 0412, La Jolla, CA 92093, USA.
Eur Heart J Digit Health ; 2(2): 311-322, 2021 Jun.
Article en En | MEDLINE | ID: mdl-34223176
ABSTRACT

AIMS:

To develop an automated method for bloodpool segmentation and imaging plane re-slicing of cardiac computed tomography (CT) via deep learning (DL) for clinical use in coronary artery disease (CAD) wall motion assessment and reproducible longitudinal imaging. METHODS AND

RESULTS:

One hundred patients who underwent clinically indicated cardiac CT scans with manually segmented left ventricle (LV) and left atrial (LA) chambers were used for training. For each patient, long-axis (LAX) and short-axis planes were manually defined by an imaging expert. A DL model was trained to predict bloodpool segmentations and imaging planes. Deep learning bloodpool segmentations showed close agreement with manual LV [median Dice 0.91, Hausdorff distance (HD) 6.18 mm] and LA (Dice 0.93, HD 7.35 mm) segmentations and a strong correlation with manual ejection fraction (Pearson r 0.95 LV, 0.92 LA). Predicted planes had low median location (6.96 mm) and angular orientation (7.96 ° ) errors which were comparable to inter-reader differences (P > 0.71). 84-97% of DL-prescribed LAX planes correctly intersected American Heart Association segments, which was comparable (P > 0.05) to manual slicing. In a test cohort of 144 patients, we evaluated the ability of the DL approach to provide diagnostic imaging planes. Visual scoring by two blinded experts determined ≥94% of DL-predicted planes to be diagnostically adequate. Further, DL-enabled visualization of LV wall motion abnormalities due to CAD and provided reproducible planes upon repeat imaging.

CONCLUSION:

A volumetric, DL approach provides multiple chamber segmentations and can re-slice the imaging volume along standardized cardiac imaging planes for reproducible wall motion abnormality and functional assessment.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Guideline / Prognostic_studies / Risk_factors_studies Idioma: En Año: 2021 Tipo del documento: Article