Your browser doesn't support javascript.
loading
An Improved LC-MS/MS Method for the Analysis of Thirteen Cytostatics on Workplace Surfaces.
Portilha-Cunha, Maria Francisca; Ramos, Sara; Silva, Adrián M T; Norton, Pedro; Alves, Arminda; Santos, Mónica S F.
  • Portilha-Cunha MF; LEPABE-Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal.
  • Ramos S; Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal.
  • Silva AMT; Laboratory of Separation and Reaction Engineering-Laboratory of Catalysis and Materials (LSRE-LCM), Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal.
  • Norton P; Departamento de Saúde Ocupacional, Centro Hospitalar Universitário São João, 4200-319 Porto, Portugal.
  • Alves A; EPIUnit, Instituto de Saúde Pública, Universidade do Porto, Rua das Taipas 135, 4050-600 Porto, Portugal.
  • Santos MSF; Departamento de Ciências da Saúde Pública e Forenses e Educação Médica, Faculdade de Medicina, Universidade do Porto, 4200-319 Porto, Portugal.
Pharmaceuticals (Basel) ; 14(8)2021 Jul 31.
Article en En | MEDLINE | ID: mdl-34451851
ABSTRACT
Cytostatics are drugs used in cancer treatment, which pose serious risks to healthcare workers. Dermal absorption via surface contamination is the key exposure route; thus, rapid, reliable, and validated analytical methods for multicomponent detection are crucial to identify the exposure risk. A surface-wipe-sampling technique compatible with hospitals' safety requirements (gauze, 1 mL isopropanol) and a fast and simple extraction method (1 mL acetonitrile, 20 min ultrasonic bath, evaporation, reconstitution in 200 µL acetonitrile), coupled with liquid chromatography-tandem mass spectrometry analysis, were developed. It allowed identification and quantification of 13 cytostatics on surfaces cyclophosphamide, doxorubicin, etoposide, ifosfamide, paclitaxel, bicalutamide, capecitabine, cyproterone, flutamide, imatinib, megestrol, mycophenolate mofetil, prednisone. Good linearity, sensitivity, and precision were achieved (R2 > 0.997, IDLs < 4.0 pg/cm2, average CV 16%, respectively). Accuracy for four model surfaces (melamine-coated wood, phenolic compact, steel 304, steel 316) was acceptable (80 ± 12%), except for capecitabine and doxorubicin. Global uncertainty is below 35% for concentrations above 100 pg/cm2 (except for capecitabine and doxorubicin)-a guidance value for relevant contamination. Method application in a Portuguese university hospital (28 samples) identified the presence of seven cytostatics, at concentrations below 100 pg/cm2, except for three samples. The widespread presence of cyclophosphamide evinces the necessity to review implemented procedures.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Año: 2021 Tipo del documento: Article