Your browser doesn't support javascript.
loading
Monobloc Dual Mobility With a Minimum 5-Year Follow-Up: A Safe and Effective Solution in Primary Total Hip Arthroplasty.
Gkiatas, Ioannis; Tarity, T David; Nocon, Allina A; Verwiel, Chloe P; Xiang, William; Malahias, Michael-Alexander; Sculco, Peter K; Sculco, Thomas P.
  • Gkiatas I; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Tarity TD; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Nocon AA; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Verwiel CP; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Xiang W; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Malahias MA; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Sculco PK; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
  • Sculco TP; Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
J Arthroplasty ; 37(1): 83-88, 2022 01.
Article en En | MEDLINE | ID: mdl-34593287
BACKGROUND: Instability constitutes over 20% of revisions after total hip arthroplasty (THA). Dual mobility (DM) designs were introduced as a solution to this problem. However, the few publications that have reported promising results for monobloc DM constructs have been limited by sample size or length of follow-up. The purpose of this study is to evaluate mid-term outcomes (minimum 5-year follow-up) of a single-surgeon series utilizing a monobloc DM acetabular component in patients with high risk for dislocation. METHODS: This is a single-surgeon consecutive series of 207 primary THAs implanted with a monobloc DM component in patients who were considered at high risk for dislocation. Patient demographics and case-specific data were collected retrospectively. All patients had a minimum of 5-year follow-up. The Mann-Whitney U test was used to assess continuous variables, whereas categorical variables were analyzed using the chi-square test. Survival probability was calculated using the Kaplan-Meier method. RESULTS: Radiographic analysis did not reveal acetabular radiolucency in any patients, and there were no revisions for aseptic loosening. In addition, there were no dislocations. Seven of 205 patients (3.4%) were revised, 5 on the femoral side due to periprosthetic fracture and the remaining two for infection. Survivorship of the acetabular component from revision was 99%. The mean Veteran RAND (VR-12) physical score improved from 7 (standard deviation [SD]: 13.7) preoperatively to 9.5 (SD: 17.6) at the final follow-up. Similarly, the hip disability osteoarthritis score improved from 8 (SD: 17.9) preoperatively to 21.2 (SD: 37). CONCLUSION: Monobloc DM components reliably prevent dislocation after primary THA in high-risk patients. At mid-term follow-up, this DM monobloc component demonstrates excellent implant survivorship, radiographic fixation, and improved functional outcomes.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article