Your browser doesn't support javascript.
loading
Recurrence of left ventricular pseudoaneurysm after multiple mitral valve replacements.
Alsomali, Afrah; Eltayeb, Abdullah; Aldosari, Sarah; AlShahid, Maie; AlSanei, Aly; AlEnazy, Ali; Vriz, Olga.
  • Alsomali A; College of Medicine, Alfaisal University, Riyadh. Afrah.m@live.com.
  • Eltayeb A; King Faisal Specialist Hospital and Research Centre, Riyadh. Abdullaheltayeb2002@gmail.com.
  • Aldosari S; College of Medicine, Alfaisal University, Riyadh. sraldosari@alfaisal.edu.
  • AlShahid M; King Faisal Specialist Hospital and Research Centre, Riyadh. maiesh55@gmail.com.
  • AlSanei A; King Faisal Specialist Hospital and Research Centre, Riyadh. sanei@kfshrc.edu.sa.
  • AlEnazy A; King Faisal Specialist Hospital and Research Centre, Riyadh. dr_alialenazy@yahoo.com.
  • Vriz O; College of Medicine, Alfaisal University, Riyadh; King Faisal Specialist Hospital and Research Centre, Riyadh. olgavriz@yahoo.com.
Monaldi Arch Chest Dis ; 92(2)2021 Oct 11.
Article en En | MEDLINE | ID: mdl-34634901
ABSTRACT
Left ventricular pseudoaneurysm (LVPA) formation is a potentially lethal complication of myocardial infarction (MI) and mitral valve (MV) replacement that requires prompt diagnosis and treatment. A female patient who had been complaining of exertional dyspnea underwent a two-dimensional transthoracic echocardiogram (TTE) which revealed a functioning mechanical MV with severe paravalvular leak, severe tricuspid regurgitation (TR) and severely elevated pulmonary artery systolic pressure. Moreover, echo-lucent space at the postero-lateral portion of the left ventricle near the MV was seen, suggestive of a large LVPA. Transesophageal echocardiography (TEE) and computed tomography (CT) angiography confirmed these findings. Afterwards, the patient had a surgical repair for the LVPA along with mitral and tricuspid valve (TV) replacement. Three months later, the patient presented with symptoms of congestive heart failure. The LVPA had recurred at the same location of the previous pseudoaneurysm and given the high risk for reoperating on the patient, close monitoring and medical management were deemed as a better option.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aneurisma Falso / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Tipo de estudio: Etiology_studies Límite: Female / Humans Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aneurisma Falso / Implantación de Prótesis de Válvulas Cardíacas / Insuficiencia de la Válvula Mitral Tipo de estudio: Etiology_studies Límite: Female / Humans Idioma: En Año: 2021 Tipo del documento: Article