ABSTRACT
PURPOSE:
To evaluate studies with a minimum follow-up of 3 years to find the peri-implant marginal bone loss (MBL) and rate of implant failure with platform-switching (PS) and platform-matching (PM) implant-abutment connections. MATERIALS ANDMETHODS:
A systematic review and meta-analysis was done based on the preferred reporting items for systematic reviews and meta-analyses guidelines, with a focused question on population, intervention, comparison, and outcome. The Cochrane Collaboration's Risk of Bias tool was used to assess bias. Randomized controlled trials (RCTs) comparing peri-implant MBL and implant failure in patients receiving PS implants and PM implants only were included. The risk ratio (RR) of the implant-abutment connection and implant failure was calculated, and peri-implant MBL was expressed in mean differences (MD) at 95% confidence intervals (CIs).RESULTS:
Three hundred eighty-one articles were obtained after an initial literature search. Finally, nine articles were included in the study that fulfilled the inclusion criteria. Four hundred twenty-six PS and 411 PM implants were placed with 16 implant failures (8 PS and 8 PM). The implant survival rate was 98.12% for the PS group, and 98.05% for the PM group, with no statistically significant difference (P = .97). The mean peri-implant MBL with the PS implant was lower (0.33 ± 0.41 mm) compared with the PM implant (0.66 ± 0.42 mm). A significant effect of PS implants was found in reducing peri-implant MBL (MD -0.70, 95% CI -1.25,-0.15; P = .01) compared with PM implants. The MD of peri-implant MBL between the PS and PM implants decreases with increased follow-up MD of 0.69 (P = .15) with follow-up of ≥ 3 years but < 5 years, and MD of 0.62 (P = .04) with follow-up of ≥ 5 years.CONCLUSION:
Reduced peri-implant MBL was found with the PS concept. The peri-implant MBL decreases with an increased mismatch between the abutment and implant platform. The difference in peri-implant MBL in PS and PM implants in the maxilla was greater and favored the PS concept. Bone-level implants with single crowns or splinted prostheses better preserved the peri-implant marginal bone with the PS concept.
Texto completo:
1
Banco de datos:
MEDLINE
Asunto principal:
Implantes Dentales
/
Pérdida de Hueso Alveolar
Tipo de estudio:
Clinical_trials
/
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Systematic_reviews
Límite:
Humans
Idioma:
En
Año:
2021
Tipo del documento:
Article