Your browser doesn't support javascript.
loading
The evaluation of bone marrow edema in sacroiliac joint in patients with ankylosing spondylitis using magnetic resonance imaging Dixon sequence.
Du, Ming-Shan; Xiong, Xuan-Qi; Liu, He; Qin, Xin; Hu, Xiao-Fei; Chen, Wei.
  • Du MS; Department of Radiology, Southwest Hospital, Third Military Medical University(Army Medical University), Chongqing, 400038, China.
  • Xiong XQ; Department of Radiology, Chenggu County Hospital, Hanzhong, 723200, China.
  • Liu H; Department of Radiology, Southwest Hospital, Third Military Medical University(Army Medical University), Chongqing, 400038, China.
  • Qin X; Department of Radiology, Southwest Hospital, Third Military Medical University(Army Medical University), Chongqing, 400038, China.
  • Hu XF; Department of Radiology, Department of Radiology, Xingyi People's Hospital of Guizhou Province, Xingyi, 562400, China.
  • Chen W; Department of Radiology, Southwest Hospital, Third Military Medical University(Army Medical University), Chongqing, 400038, China. harryzonetmmu@163.com.
BMC Musculoskelet Disord ; 22(1): 919, 2021 Nov 01.
Article en En | MEDLINE | ID: mdl-34724925
ABSTRACT

BACKGROUND:

Bone marrow edema of the sacroiliac joint is the early imaging manifestation, an indicator of inflammatory activity of ankylosing spondylitis (AS) (Yang R, et. al. Medicine (Baltimore) 98e14620, 2019).

OBJECTIVE:

The aim of the study was to investigate the value of magnetic resonance imaging (MRI) Dixon sequence in the diagnosis of marrow edema of the sacroiliac joint in patients with AS.

METHODS:

Forty-five patients with AS admitted in our hospital between November 2016 and February 2019 were selected retrospectively as the case group. Forty-five healthy subjects recruited between November 2016 and February 2019 served as the control group. Bath ankylosing spondylitis disease activity index (BASDAI), Bath ankylosing spondylitis functional index (BASFI), C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were recorded after admission to the hospital. The Dixon sequence water-fat ratio of the iliac and sacral surfaces of the bilateral sacroiliac joints in the study group were compared with indicators above in order to find the correlation.

RESULTS:

The water-fat ratio under the bilateral sacroiliac joints on Dixon sequence images in the case group was significantly higher than that in the healthy control group (P<0.05). The Dixon sequence water-fat ratio of the iliac and sacral surfaces of the bilateral sacroiliac joints in the study group were positively correlated with spinal arthritis research (SPARCC), BASFI and BASDAI score (all P < 0.05), but did not correlate with ESR and CRP.

CONCLUSION:

The water-fat ratio of magnetic resonance Dixon sequence can be used as a reference index to evaluate the degree of bone marrow edema in active stage of sacroiliac arthritis.