Your browser doesn't support javascript.
loading
Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up.
El-Chami, Mikhael F; Bockstedt, Lindsay; Longacre, Colleen; Higuera, Lucas; Stromberg, Kurt; Crossley, George; Kowal, Robert C; Piccini, Jonathan P.
  • El-Chami MF; Emory University School of Medicine, 550 W Peachtree St NE, Atlanta, GA 30308, USA.
  • Bockstedt L; Medtronic, Inc, 710 Medtronoc PKW NE, Minneapolis, MN 55432, USA.
  • Longacre C; Medtronic, Inc, 710 Medtronoc PKW NE, Minneapolis, MN 55432, USA.
  • Higuera L; Medtronic, Inc, 710 Medtronoc PKW NE, Minneapolis, MN 55432, USA.
  • Stromberg K; Medtronic, Inc, 710 Medtronoc PKW NE, Minneapolis, MN 55432, USA.
  • Crossley G; Vanderbilt University Medical Center, 1161 21ST Ave S, Nashville, TN 37232, USA.
  • Kowal RC; Medtronic, Inc, 710 Medtronoc PKW NE, Minneapolis, MN 55432, USA.
  • Piccini JP; Duke University Medical Center & Duke Clinical Research Institute, 40 Duke Medicine Circle Clinic 2F/2 G, Durham, NC 27710, USA.
Eur Heart J ; 43(12): 1207-1215, 2022 Mar 21.
Article en En | MEDLINE | ID: mdl-34788416
ABSTRACT

AIMS:

Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. METHODS AND

RESULTS:

The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data (n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims (n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45-0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60-0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91-1.04, P = 0.37).

CONCLUSION:

In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Estimulación Cardíaca Artificial Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans País como asunto: America do norte Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Estimulación Cardíaca Artificial Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Humans País como asunto: America do norte Idioma: En Año: 2022 Tipo del documento: Article