Aorta-coronary bypass grafting with polytetrafluoroethylene conduits. Early and late outcome in eight patients.
J Thorac Cardiovasc Surg
; 94(1): 132-4, 1987 Jul.
Article
en En
| MEDLINE
| ID: mdl-3496497
ABSTRACT
During 1982 and 1983 we performed aorta-coronary bypass grafts on eight patients using 4 mm polytetrafluoroethylene conduits and predominantly the multiple sequential graft technique. Angiography was performed 1 week postoperatively and seven of eight patients had patent grafts and were angina free. At 1 year's follow-up 18 of 28 distal anastomoses were patent and five of eight patients were angina free. At 45 month's follow-up four of 28 distal anastomoses were patent and one of eight patients was angina free.
Search on Google
Banco de datos:
MEDLINE
Asunto principal:
Politetrafluoroetileno
/
Prótesis Vascular
/
Puente de Arteria Coronaria
/
Oclusión de Injerto Vascular
/
Angina de Pecho
Tipo de estudio:
Observational_studies
/
Prognostic_studies
Límite:
Humans
Idioma:
En
Año:
1987
Tipo del documento:
Article