Your browser doesn't support javascript.
loading
A reversed-phase ultra-fast liquid chromatography-photodiode array detector (RP-UFLC-PDA) method for simultaneous estimation of ayapanin and umbelliferone in Ayapana triplinervis Vahl.
Biswas, Sayan; Kar, Amit; Chanda, Joydeb; Sharma, Nanaocha; Bharadwaj, Pardeep Kumar; Haldar, Pallab Kanti; Mukherjee, Pulok Kumar.
  • Biswas S; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
  • Kar A; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
  • Chanda J; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
  • Sharma N; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
  • Bharadwaj PK; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
  • Haldar PK; School of Natural Product Studies, Department of Pharmaceutical Technology, Jadavpur University, Kolkata, India.
  • Mukherjee PK; An Autonomous Institute under the Department of Biotechnology, Government of India, Institute of Bioresources and Sustainable Development, Imphal, Manipur, India.
Biomed Chromatogr ; 36(5): e5328, 2022 May.
Article en En | MEDLINE | ID: mdl-34997595
ABSTRACT
A rapid validated ultra-fast liquid chromatography-photodiode array detector (UFLC-PDA) method was developed to identify and quantify ayapanin (AY) and umbelliferone (UM) simultaneously in Ayapana triplinervis Vahl methanolic extract. The method was validated for linearity, limit of detection (LOD; 31σ/S), limit of quantification (LOQ; 101σ/S), precision, accuracy, specificity and robustness. The response was linear with a good correlation between concentration and mean peak area through a correlation coefficient of 0.9996, y = 7025.7x - 2269.8 and 0.9997, y = y = 16,262x - 946 with LOD of 6.256 ± 0.52 and 3.325 ± 0.36, and LOQ of 18.838 ± 0.18 and 8.870 ± 0.85 for AY (0.67% w/w) and UM (0.18% w/w), respectively. The relative standard deviation (%) of precision and recovery of AY and UM was <2.0%. The proposed method was simple, accurate, specific, precise and reproducible.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Cromatografía de Fase Inversa Tipo de estudio: Prognostic_studies Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Cromatografía de Fase Inversa Tipo de estudio: Prognostic_studies Idioma: En Año: 2022 Tipo del documento: Article