High Speed Mass Measurement of a Single Metal-Organic Framework Nanocrystal in a Paul Trap.
Xiong, Caiqiao; Liu, Huihui; Li, Yuze; Meng, Lingwei; Wang, Jiyun; Nie, Zongxiu.
  • Xiong C; Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.
  • Liu H; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Li Y; Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.
  • Meng L; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Wang J; Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.
  • Nie Z; University of Chinese Academy of Sciences, Beijing 100049, China.
Anal Chem ; 94(6): 2686-2692, 2022 02 15.
Article en En | MEDLINE | ID: mdl-35112854
ABSTRACT
Mass spectrometry (MS) has emerged as an excellent tool for the characterization of metal-organic frameworks (MOFs) based on the characteristic metal ions and organic ligands. Mass measurement of intact MOF nanocrystals, however, remains a challenge for MS technology. Here, we reported the development of a probe particles based charge detection-quadrupole ion trap mass spectrometry (probe CD-QIT MS) method, where charge detection and mass measurement of a single MOF nanocrystal were achieved under the assistance of probe particles of micrometer size. As a validation of the method, the masses of a series of polystyrene (PS) size standards from 493 nm to 1.6 µm were measured with 3 µm PS particles as probes, and the measured masses were found to match well with their certified masses. Then, charge detections and mass analysis of single ZIF-8 and GOx@ZIF-8 with a size around 600 nm were achieved successfully. The method presented here demonstrates simplicity, high speed, and accuracy. Notably, it allows quantitative measurement of the amount of immobilized GOx enzyme by using the mass difference between ZIF-8 and GOx@ZIF-8. In addition, based on the determined mass, the size analysis of these MOF particles with irregular shape was carried out and demonstrated to be complementary to transmission electron microscopy (TEM).
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nanopartículas / Estructuras Metalorgánicas Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Nanopartículas / Estructuras Metalorgánicas Idioma: En Año: 2022 Tipo del documento: Article