Your browser doesn't support javascript.
loading
Investigation of the Oxidation Behavior of Cr20Mn17Fe18Ta23W22 and Microdefects Evolution Induced by Hydrogen Ions before and after Oxidation.
Wu, Bao-Zhen; Zhu, Te; Cao, Xing-Zhong; Yang, Zhao-Ming; Zhang, Kun; Gou, Fu-Jun; Wang, Yuan.
  • Wu BZ; Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China.
  • Zhu T; Multi-Disciplinary Research Center, Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China.
  • Cao XZ; Multi-Disciplinary Research Center, Institute of High Energy Physics, Chinese Academy of Sciences (CAS), Beijing 100049, China.
  • Yang ZM; Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China.
  • Zhang K; Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China.
  • Gou FJ; Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China.
  • Wang Y; Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China.
Materials (Basel) ; 15(5)2022 Mar 03.
Article en En | MEDLINE | ID: mdl-35269123
The oxidation behavior of body-centered cubic (bcc) structure Cr20Mn17Fe18Ta23W22 refractory high-entropy alloy (RHEA) and the microdefects induced by hydrogen ions before and after oxidation were investigated. The results revealed that compared with oxidizing Cr20Mn17Fe18Ta23W22 at 800 °C (6.7 °C/min) for 4 h (ST3, Ar:O2 = 3:1), the heating procedure of oxidizing Cr20Mn17Fe18Ta23W22 at 300 °C (6 °C/min) for 2 h and then increased to 800 °C (5 °C/min) for 4 h is more conducive to the production of oxides without spalling on the surface, i.e., HT1 (Ar:O2 = 1:1), HT2 (Ar:O2 = 2:1) and HT3 (Ar:O2 = 3:1) samples. The oxidation of Cr20Mn17Fe18Ta23W22 RHEA is mainly controlled by the diffusion of cations instead of affinities with O. Additionally, HT1 and HT3 samples irradiated with a fluence of 3.9 × 1022 cm-2 hydrogen ions (60 eV) were found to have a better hydrogen irradiation resistance than Cr20Mn17Fe18Ta23W22 RHEA. The microdefects in irradiated Cr20Mn17Fe18Ta23W22 mainly existed as hydrogen bubbles, hydrogen-vacancy (H-V) complexes and vacancy/vacancy clusters. The microdefects in irradiated HT3 were mainly vacancies and H-V complexes, while the microdefects in irradiated HT1 mainly existed as vacancies and vacancy clusters, as large amounts of hydrogen were consumed to react with oxides on the HT1 surface. The oxides on the surface of the HT3 sample were more stable than those on HT1 under hydrogen irradiation.
Palabras clave