Your browser doesn't support javascript.
loading
A novel surgical planning system using an AI model to optimize planning of pedicle screw trajectories with highest bone mineral density and strongest pull-out force.
Ma, Chi; Zou, Da; Qi, Huan; Li, Chentian; Zhang, Cheng; Yang, Kedi; Zhu, Feng; Li, Weishi; Lu, William W.
  • Ma C; 1Department of Orthopaedics & Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong.
  • Zou D; 2Orthopaedic Department and.
  • Qi H; 3Beijing Key Laboratory of Spinal Disease Research, Peking University Third Hospital, Beijing.
  • Li C; 4Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Peking University Third Hospital, Beijing.
  • Zhang C; 1Department of Orthopaedics & Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong.
  • Yang K; 5Department of Orthopaedics and Traumatology, Zhujiang Hospital, Southern Medical University, Guangzhou; and.
  • Zhu F; 1Department of Orthopaedics & Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong.
  • Li W; 1Department of Orthopaedics & Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong.
  • Lu WW; 1Department of Orthopaedics & Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong.
Neurosurg Focus ; 52(4): E10, 2022 04.
Article en En | MEDLINE | ID: mdl-35364575
ABSTRACT

OBJECTIVE:

The purpose of this study was to evaluate the ability of a novel artificial intelligence (AI) model in identifying optimized transpedicular screw trajectories with higher bone mineral density (BMD) as well as higher pull-out force (POF) in osteoporotic patients.

METHODS:

An innovative pedicle screw trajectory planning system called Bone's Trajectory was developed using a 3D graphic search and an AI-based finite element analysis model. The preoperative CT scans of 21 elderly osteoporotic patients were analyzed retrospectively. The AI model automatically calculated the number of alternative transpedicular trajectories, the trajectory BMD, and the estimated POF of L3-5. The highest BMD and highest POF of optimized trajectories were recorded and compared with AO standard trajectories.

RESULTS:

The average patient age and average BMD of the vertebral bodies were 69.6 ± 7.8 years and 55.9 ± 17.1 mg/ml, respectively. On both sides of L3-5, the optimized trajectories showed significantly higher BMD and POF than the AO standard trajectories (p < 0.05). On average, the POF of optimized trajectory screws showed at least a 2.0-fold increase compared with AO trajectory screws.

CONCLUSIONS:

The novel AI model performs well in enabling the selection of optimized transpedicular trajectories with higher BMD and POF than the AO standard trajectories.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fusión Vertebral / Tornillos Pediculares Tipo de estudio: Observational_studies Límite: Aged / Humans Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fusión Vertebral / Tornillos Pediculares Tipo de estudio: Observational_studies Límite: Aged / Humans Idioma: En Año: 2022 Tipo del documento: Article