The value of contrast-enhanced ultrasound in the diagnosis of BI-RADS-US 4a lesions less than 2 cm in diameter.
Yu, Mei-Qin; Zhang, Li-Li; Jiang, Li-Ping; Zhou, Ai-Yun.
  • Yu MQ; Department of Ultrasound Medicine, The First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China.
  • Zhang LL; Department of Ultrasound Medicine, The First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China.
  • Jiang LP; Department of Ultrasound Medicine, The First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China.
  • Zhou AY; Department of Ultrasound Medicine, The First Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China.
Clin Hemorheol Microcirc ; 83(3): 195-205, 2023.
Article en En | MEDLINE | ID: mdl-35599475
BACKGROUND: Breast cancer is the most common malignant tumor in women. Early diagnosis of benign and malignant breast tumors is of great significance. OBJECTIVE: To retrospectively analyze the value of contrast-enhanced ultrasonography (CEUS) in the diagnosis of Breast Imaging-Reporting and Data System (BI-RADS) 4a breast lesions less than 2 cm in diameter. METHODS: CEUS was performed for 143 breast masses less than 2 cm in diameter that were diagnosed as BI-RADS 4a by ultrasound and reclassified. Considering pathological diagnosis as the gold standard, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of reclassified lesions after CEUS for the diagnosis of benign and malignant masses were analyzed. RESULTS: BI-RADS 4a breast masses with a diameter less than 2 cm (n = 143) were confirmed by pathology; 103 and 40 were classified as benign and malignant, respectively. The sensitivity, specificity, PPV, and NPV of CEUS for the diagnosis were 90%, 86%, 72%, and 95%, respectively. The area under the receiver operating characteristic (ROC) curve of CEUS for the diagnosis of benign and malignant tumors after CEUS was 0.904. CONCLUSION: CEUS can help to improve the diagnostic accuracy of BI-RADS 4a masses with a diameter less than 2 cm.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Ultrasonografía Mamaria Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Límite: Female / Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Ultrasonografía Mamaria Tipo de estudio: Diagnostic_studies / Prognostic_studies / Screening_studies Límite: Female / Humans Idioma: En Año: 2023 Tipo del documento: Article