Your browser doesn't support javascript.
loading
Separation of planar chiral ferrocenes by capillary electrokinetic chromatography and liquid chromatography.
Morvan, Antoine; Garnier, Camille; Furman, Christophe; Speybrouck, David; Boulanger, Eric; Ghinet, Alina; Lipka, Emmanuelle.
  • Morvan A; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France.
  • Garnier C; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France.
  • Furman C; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France.
  • Speybrouck D; Oril industrie-Servier, 13 rue A. Desgenetais, F-76210 Bolbec, France.
  • Boulanger E; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France.
  • Ghinet A; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France; JUNIA, Health & Environment, Laboratory of Sustainable Chemistry and Health, F-59000 Lille, France; Alexandru Ioan Cuza' University of Iasi
  • Lipka E; Univ. Lille, CHU Lille, Inserm, Institut Pasteur de Lille, U1167 - Risk factors and molecular determinants of aging-related diseases, F-59000 Lille, France. Electronic address: emmanuelle.lipka@univ-lille.fr.
J Chromatogr A ; 1677: 463306, 2022 Aug 16.
Article en En | MEDLINE | ID: mdl-35810641
ABSTRACT
Capillary electrokinetic chromatography (CEKC) and liquid chromatography (LC) methods were explored for the enantiomeric separation of six unsymmetrically disubstituted ferrocene derivatives. In normal-phase mode liquid chromatography, the use of n-heptane, ethanol or isopropanol with 1% n-butylamine as mobile phase on six polysaccharide-based columns, allowed to fully separate the enantiomers of three compounds out of the six (i.e 7-chloro-N-(2-((dimethylamino)methyl)ferrocenyl)quinolin-4-amine (ferroquine) (compound 1), 1-[(1S)-(1-Aminoethyl)]-2-(diphenylphosphino)ferrocene (compound 5) and 1-[(1R)-1-(Dicyclohexylphosphino)ethyl]-2-(diphenylphosphino)ferrocene (compound 6). Among the columns used, the Lux i-Cellulose-5 was the most effective. In capillary electrokinetic chromatography, a phosphate buffer of 25 mM concentration and pH equal to 2.5 was chosen as background electrolyte, leading to cationic ferrocene derivatives. The addition of neutral cyclodextrins was undertaken first and native ß- or γ-cyclodextrins were found to resolve the enantiomers of two derivatives. Then, 15 mM of anionic cyclodextrins were added to the background electrolyte. The use of SBE-ß-CD, S-ß-CD or S-γ-CD have allowed the separation of the enantiomers for most of the ferrocene derivatives studied with high resolution values in short migration time. For instance, for 1-(R)-2-(Diphenylphosphino)ethyldi-tert-butylphosphine ferrocene (compound 2), the migration times were less than 2 minutes and the resolution value was equal to 3.52 in short-end mode with 15 mM S-ß-CD, at 25 kV and 25°C. Finally, a dual cyclodextrins system was tested using 15 mM of S-ß-CD plus 15 mM HP-γ-CD in the phosphate buffer. This system allowed the improved separation of two ferrocene derivatives with an unusual resolution value equal to 41.5 in long-end mode. Overall, CEKC showed better enantioseparating power of the six chiral ferrocenes studied than liquid chromatography.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ciclodextrinas Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ciclodextrinas Idioma: En Año: 2022 Tipo del documento: Article