Your browser doesn't support javascript.
loading
Hybrid Effect of Steel Bars and PAN Textile Reinforcement on Ductility of One-Way Slab Subjected to Bending.
Hussein, Omar H; Ibrahim, Amer M; Abd, Suhad M; Najm, Hadee Mohammed; Shamim, Saba; Sabri, Mohanad Muayad Sabri.
  • Hussein OH; Department of Civil Engineering, College of Engineering, University of Diyala, Baqubah 32001, Iraq.
  • Ibrahim AM; Department of Civil Engineering, College of Engineering, University of Diyala, Baqubah 32001, Iraq.
  • Abd SM; Department of Civil Engineering, College of Engineering, University of Diyala, Baqubah 32001, Iraq.
  • Najm HM; Department of Civil Engineering, Zakir Husain College of Engineering and Technology, F/O Engineering and Technology, Aligarh Muslim University, Aligarh 202002, India.
  • Shamim S; Department of Civil Engineering, Zakir Husain College of Engineering and Technology, F/O Engineering and Technology, Aligarh Muslim University, Aligarh 202002, India.
  • Sabri MMS; Peter the Great St. Petersburg Polytechnic University, St. Petersburg 195251, Russia.
Molecules ; 27(16)2022 Aug 15.
Article en En | MEDLINE | ID: mdl-36014448
ABSTRACT
Textile reinforced concrete (TRC) has gained attention from the construction industry due to several characteristics such as its lightweight, high tensile strength, design flexibility, corrosion resistance and remarkably long service life. Some structural applications that utilize TRC components include precast panels, structural repairs, waterproofing elements and façades. TRC is produced by incorporating textile fabrics into thin cementitious concrete panels. However, in order to use this strengthening method in construction practice, a design model is required. Investigating the combined effect of conventional steel and textile reinforcement on the ductility behavior of composite TRC/RC one-way slab is vitally important. Therefore, the current study describes the proper methods of calculating the ductility of the composite concrete reinforced by a direct combination of conventional steel and textile reinforcement. Four methods are presented to calculate the ductility of the three considered one-way slab specimens. The three slabs having dimensions 1500 mm × 500 mm × 50 mm were reinforced by steel bars (SRC), by steel with one layer of carbon fabric (SRC + 1T), and by steel with two layers of carbon fabric (SRC + 2T). The three slab specimens were cast by the hand lay-up method, removed from the molds, cured, and then tested in flexure after 28 days using the four-point bending method. The obtained results and calculations revealed the non-reasonability of using the conventional method based on yielding of steel reinforcement as the only criterion in the ductility determination. The results also confirmed the suitability of using the energy-based method over other discussed methods in the calculation of the ductility for the hybrid reinforced members.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Año: 2022 Tipo del documento: Article