Comparison of platelet count results on the Sysmex XN between citrate or MgSO4 and K2 EDTA anticoagulants.
Soulard, Michel; Croix, Pascale; Cohen, Patrick.
  • Soulard M; Biogroup Hematology Laboratory, La Chocolaterie, Levallois Perret, France.
  • Croix P; Biogroup Hematology Laboratory, La Chocolaterie, Levallois Perret, France.
  • Cohen P; Division of Laboratory Medicine, Diagnostic Department, Geneva University Hospitals and Faculty of Medicine, Geneva, Switzerland.
Int J Lab Hematol ; 45(1): 20-28, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36093831
ABSTRACT

INTRODUCTION:

The aim of this study performed on Sysmex XN is to compare platelet values on citrate and MgSO4 (TBX) in patients with K2EDTA-induced platelet clusters and to identify platelet biases of these matrices compared to K2EDTA.

METHODS:

Sixty patients with K2EDTA-induced platelet clusters were re-sampled with K2EDTA, citrate and TBX. Platelet results were then compared, and smears were analysed for clumping. Platelet results from 120 patients without K2EDTA-induced platelet clusters were compared between K2 EDTA, citrate, and MgSO4 with impedance and fluorescence modes. Biases from regressions were analysed.

RESULTS:

Out of the 60 patients with K2EDTA-induced platelet clusters, none showed platelet clusters with MgSO4 whereas 50% still showed clusters with citrate. Among those without platelet clusters on citrate, the mean relative difference between (citrate- MgSO4 )/MgSO4 was -12.7% in impedance and -9.8% in fluorescence. Among the 120 patients without K2EDTA-induced platelet clusters, in fluorescence the mean relative bias with respect to K2EDTA was -2.06% for MgSO4 and -10.3% for Citrate. For the MgSO4 versus K2 EDTA regressions, the maximum absolute values of the 95% CI of the relative biases at 150 × 109 /L (5.45%) and 450 × 109 /L (3.56%) were below the desirable analytical objectives of the EFLM.

CONCLUSION:

In patients with K2EDTA-induced platelet clusters, MgSO4 is preferable to citrate. MgSO4 provides a bias with XN in fluorescence when compared to EDTA which is within analytical tolerance.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ácido Cítrico / Anticoagulantes Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ácido Cítrico / Anticoagulantes Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article