Your browser doesn't support javascript.
loading
Quality Improvement in the Preoperative Evaluation: Accuracy of an Automated Clinical Decision Support System to Calculate CHA2DS2-VASc Scores.
van Giersbergen, Chantal; Korsten, Hendrikus H M; De Bie Dekker, Ashley J R; Mestrom, Eveline H J; Bouwman, R Arthur.
  • van Giersbergen C; Department of Anesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands.
  • Korsten HHM; Department of Anesthesiology, Maastricht University Hospital, 6229 HX Maastricht, The Netherlands.
  • De Bie Dekker AJR; Department of Anesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands.
  • Mestrom EHJ; Department of Signal Processing Systems and Electrical Engineering, Signal Processing Systems TU/e University of Technology, 5612 AZ Eindhoven, The Netherlands.
  • Bouwman RA; Department of Anesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, 5623 EJ Eindhoven, The Netherlands.
Medicina (Kaunas) ; 58(9)2022 Sep 13.
Article en En | MEDLINE | ID: mdl-36143945
ABSTRACT
Background and

Objectives:

Clinical decision support systems are advocated to improve the quality and efficiency in healthcare. However, before implementation, validation of these systems needs to be performed. In this evaluation we tested our hypothesis that a computerized clinical decision support system can calculate the CHA2DS2-VASc score just as well compared to manual calculation, or even better and more efficiently than manual calculation in patients with atrial rhythm disturbances. Materials and

Methods:

In n = 224 patents, we calculated the total CHA2DS2-VASc score manually and by an automated clinical decision support system. We compared the automated clinical decision support system with manually calculation by physicians.

Results:

The interclass correlation between the automated clinical decision support system and manual calculation showed was 0.859 (0.611 and 0.931 95%-CI). Bland-Altman plot and linear regression analysis shows us a bias of -0.79 with limit of agreement (95%-CI) between 1.37 and -2.95 of the mean between our 2 measurements. The Cohen's kappa was 0.42. Retrospective analysis showed more human errors than algorithmic errors. Time it took to calculate the CHA2DS2-VASc score was 11 s per patient in the automated clinical decision support system compared to 48 s per patient with the physician.

Conclusions:

Our automated clinical decision support system is at least as good as manual calculation, may be more accurate and is more time efficient.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fibrilación Atrial / Sistemas de Apoyo a Decisiones Clínicas / Accidente Cerebrovascular Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fibrilación Atrial / Sistemas de Apoyo a Decisiones Clínicas / Accidente Cerebrovascular Tipo de estudio: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article