Your browser doesn't support javascript.
loading
Semi-crystalline microplastics in wastewater plant effluents and removal efficiencies of post-treatment filtration systems.
Bitter, Hajo; Krause, Leonie; Kirchen, Franziska; Fundneider, Thomas; Lackner, Susanne.
  • Bitter H; Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Franziska-Braun-Strasse 7, Darmstadt 64287, Germany.
  • Krause L; Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Franziska-Braun-Strasse 7, Darmstadt 64287, Germany.
  • Kirchen F; Weber-Ingenieure GmbH, Darmstadt, Germany.
  • Fundneider T; Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Franziska-Braun-Strasse 7, Darmstadt 64287, Germany.
  • Lackner S; Department of Civil and Environmental Engineering Sciences, Institute IWAR, Chair of Water and Environmental Biotechnology, Technical University of Darmstadt, Franziska-Braun-Strasse 7, Darmstadt 64287, Germany.
Water Res X ; 17: 100156, 2022 Dec 01.
Article en En | MEDLINE | ID: mdl-36177246
Microplastics (MPs) are ubiquitous in the environment and have been found in every environmental compartment. Wastewater and wastewater treatment plants (WWTPs) have been identified as possible point sources contributing to the emission of microplastic particles (MPP) into the aquatic environment. So far, MPP in wastewater effluents have mainly been analyzed by spectroscopic methods resulting in concentrations as number per volume. In this study, we present mass concentrations in the secondary effluents of four German municipal WWTPs, removal efficiencies of seven post-treatment systems and the resulting load emissions. Differential Scanning Calorimetry (DSC) was used for the analysis of semi-crystalline MPs. The concentrations of secondary effluents ranged from 0.1 to 19.6 µg L-1. Removal efficiencies > 94% were found for a microfiltration membrane (MF), two cloth types of a pile cloth media filter (PCMF), a micro strainer, a discontinuous downflow granulated activated carbon filter (GAC) and a powdered activated carbon (PAC) stage with clarifier and rapid sand filtration. A rapid sand filter (RSF) at WWTP B showed a removal efficiency of 82.38%. Only a continuous upflow GAC filter at WWTP C proved to be unsuitable for MP removal with an average removal efficiency of 1.9%.
Palabras clave