Quantification of canakinumab in human plasma by liquid chromatography-high resolution mass spectrometry.
Millet, Aurélien; Pescarmona, Rémi; Belot, Alexandre; Machon, Christelle; Jamilloux, Yvan; Guitton, Jérôme.
  • Millet A; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Pescarmona R; Immunology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France.
  • Belot A; Pediatric Nephrology, Rheumatology, Dermatology Unit, Hôpital Femme Mère Enfant, Hospices Civils de Lyon, Lyon, France; Lyon Immunopathology FEderation (LIFE), Lyon, France.
  • Machon C; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France; Analytical Chemistry Laboratory, Faculty of Pharmacy ISPBL, University Lyon 1, F-69373 Lyon, France.
  • Jamilloux Y; Lyon Immunopathology FEderation (LIFE), Lyon, France; Internal Medicine, Hôpital de La Croix-Rousse, Hospices Civils de Lyon, Lyon, France.
  • Guitton J; Biochemistry and Pharmacology-Toxicology Laboratory, Lyon-Sud Hospital, Hospices Civils de Lyon, F-69495 Pierre Bénite, France; Toxicology Laboratory, Faculty of Pharmacy ISPBL, University of Lyon 1, F-69373 Lyon, France. Electronic address: jerome.guitton@univ-lyon1.fr.
Article en En | MEDLINE | ID: mdl-36179539
ABSTRACT
Canakinumab is a fully-human monoclonal immunoglobulin gamma 1 kappa. This interleukin-1ß blocker is used for the treatment of autoinflammatory diseases. Various studies have demonstrated the value of therapeutic drug monitoring of monoclonal antibodies in the management of inflammatory diseases. The purpose of this study was to develop a method to quantify canakinumab plasmatic concentration using liquid chromatography-high-resolution (Orbitrap®) mass spectrometry. The quantification was based on a bottom-up approach with the analysis of one surrogate peptide after an immunopurification of IgG followed by tryptic proteolysis. Rituximab and cetuximab, both IgG1, were tested as internal standards. Chromatographic separation was performed on a bioZenTM Peptide PS-C18 column. Mass detection was conducted in positive ionization mode with Parallel Reaction Monitoring at a resolution of 70,000. The method was fully validated in terms of linearity, sensitivity, selectivity, accuracy and matrix effect. Standards ranged from 2.5 to 75 µg/mL. Intra- and inter-day coefficients of variation ranged from 3.7 to 14.7 %, and accuracy from 97.4 to 104.1 %. This method allowed the determination of canakinumab plasmatic concentrations from eight treated patients. This method is efficient and suitable for routine use in therapeutic drug monitoring or pharmacokinetic studies.