Your browser doesn't support javascript.
loading
Robust and high-throughput lipidomic quantitation of human blood samples using flow injection analysis with tandem mass spectrometry for clinical use.
Idkowiak, Jakub; Jirásko, Robert; Kolárová, Denisa; Bártl, Josef; Hájek, Tomás; Antonelli, Michela; Vanková, Zuzana; Wolrab, Denise; Hrstka, Roman; Studentová, Hana; Melichar, Bohuslav; Pesková, Karolína; Holcapek, Michal.
  • Idkowiak J; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Jirásko R; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic. robert.jirasko@upce.cz.
  • Kolárová D; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Bártl J; Department of Pediatrics and Inherited Metabolic Disorders, Charles University, First Faculty of Medicine and General University Hospital in Prague, Ke Karlovu 2, 12808 2, Prague, Czech Republic.
  • Hájek T; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Antonelli M; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Vanková Z; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Wolrab D; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
  • Hrstka R; Research Centre for Applied Molecular Oncology, Masaryk Memorial Cancer Institute, Zlutý kopec 7, 656 53, Brno, Czech Republic.
  • Studentová H; Medical School and Teaching Hospital, Department of Oncology, Palacký University, I.P. Pavlova 6, 775 20, Olomouc, Czech Republic.
  • Melichar B; Medical School and Teaching Hospital, Department of Oncology, Palacký University, I.P. Pavlova 6, 775 20, Olomouc, Czech Republic.
  • Pesková K; Department of Pediatrics and Inherited Metabolic Disorders, Charles University, First Faculty of Medicine and General University Hospital in Prague, Ke Karlovu 2, 12808 2, Prague, Czech Republic.
  • Holcapek M; Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic.
Anal Bioanal Chem ; 415(5): 935-951, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36598539
ABSTRACT
Direct infusion of lipid extracts into the ion source of a mass spectrometer is a well-established method for lipid analysis. In most cases, nanofluidic devices are used for sample introduction. However, flow injection analysis (FIA) based on sample infusion from a chromatographic pump can offer a simple alternative to shotgun-based approaches. Here, we describe important modification of a method based on FIA and tandem mass spectrometry (MS/MS). We focus on minimizing contamination of the FIA/MS both to render the lipidomic platform more robust and to increase its capacity and applicability for long-sequence measurements required in clinical applications. Robust validation of the developed method confirms its suitability for lipid quantitation in human plasma analysis. Measurements of standard human plasma reference material (NIST SRM 1950) and a set of plasma samples collected from kidney cancer patients and from healthy volunteers yielded highly similar results between FIA-MS/MS and ultra-high-performance supercritical fluid chromatography (UHPSFC)/MS, thereby demonstrating that all modifications have practically no effect on the statistical output. Newly modified FIA-MS/MS allows for the quantitation of 141 lipid species in plasma (11 major lipid classes) within 5.7 min. Finally, we tested the method in a clinical laboratory of the General University Hospital in Prague. In the clinical setting, the method capacity reached 257 samples/day. We also show similar performance of the classification models trained based on the results obtained in clinical settings and the analytical laboratory at the University of Pardubice. Together, these findings demonstrate the high potential of the modified FIA-MS/MS for application in clinical laboratories to measure plasma and serum lipid profiles.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Lipidómica Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrometría de Masas en Tándem / Lipidómica Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article