Your browser doesn't support javascript.
loading
Room-Temperature Optoelectronic Gas Sensor Based on Core-Shell g-C3N4@WO3 Heterocomposites for Efficient Ammonia Detection.
Zou, Zongsheng; Zhao, Zhihui; Zhang, Ziqi; Tian, Weiliang; Yang, Chao; Jin, Xingjian; Zhang, Kewei.
  • Zou Z; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
  • Zhao Z; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
  • Zhang Z; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
  • Tian W; Key Laboratory of Chemical Engineering in South Xinjiang, College of Life Science, Tarim University, Alar843300, P. R. China.
  • Yang C; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
  • Jin X; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
  • Zhang K; State Key Laboratory of Bio-Fibers and Eco-Textiles, College of Materials Science and Engineering, Qingdao University, Qingdao266071, P. R. China.
Anal Chem ; 2023 Jan 09.
Article en En | MEDLINE | ID: mdl-36622101
ABSTRACT
The ever-growing modern industry promotes the evolution of gas sensors for environmental monitoring and safety inspection. However, traditional chemiresistive gas sensors still suffer from drawbacks of high power consumption and detection limit, mainly due to the insufficient charge-transfer ability of gas-sensing materials. Here, an optoelectronic gas sensor that can detect ppb-level ammonia at room temperature is constructed based on core-shell g-C3N4@WO3 heterocomposites. The growth of WO3 nanosheets on graphitic g-C3N4 nanosheets was precisely controlled, achieving well-defined g-C3N4@WO3 core-shell architectures. Based on the synergism between light activation and the amplification effect of in situ-formed heterojunctions, the g-C3N4@WO3 sensor exhibits improved sensing characteristics for reliable ammonia detection. As compared with the pristine g-C3N4 sensor, the sensor response toward ammonia is enhanced 21 times and the detection limit is reduced from 308 to 108 ppb. This work provides a successful approach for the in situ formation of core-shell g-C3N4@WO3 interfacial composites and offers an easy solution for the rational design of advanced optoelectronic gas sensors.

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Año: 2023 Tipo del documento: Article