Your browser doesn't support javascript.
loading
Impact of pectus excavatum on pulmonary function and exercise capacity in patients treated with 3D custom-made silicone implants.
Dupuis, M; Daussy, L; Noel-Savina, E; Dahan, M; Didier, A; Chavoin, J P; Guibert, N.
  • Dupuis M; Pulmonology Department, University Hospital of Toulouse, 24, chemin de Pouvourville, 31059 Toulouse, France.
  • Daussy L; Pulmonology Department, Albi Hospital, Albi, France.
  • Noel-Savina E; Pulmonology Department, University Hospital of Toulouse, 24, chemin de Pouvourville, 31059 Toulouse, France.
  • Dahan M; Thoracic surgery Department, Toulouse University Hospital, Toulouse, France.
  • Didier A; Pulmonology Department, University Hospital of Toulouse, 24, chemin de Pouvourville, 31059 Toulouse, France.
  • Chavoin JP; Plastic surgery Department, Toulouse University Hospital, Toulouse, France.
  • Guibert N; Pulmonology Department, University Hospital of Toulouse, 24, chemin de Pouvourville, 31059 Toulouse, France. Electronic address: guibert.n@chu-toulouse.fr.
Ann Chir Plast Esthet ; 69(1): 53-58, 2024 Jan.
Article en En | MEDLINE | ID: mdl-36737354
ABSTRACT

BACKGROUND:

Pectus excavatum (PE) is the most common congenital chest wall deformity, whose cardiopulmonary consequences are controversial. PE surgery is in our experience usually performed for aesthetic reasons.

OBJECTIVES:

The aim of this study was to evaluate the impact of PE on respiratory function and exercise capacity in patients with PE before patient-specific silicone implant correction.

METHODS:

This monocentric prospective study conducted at Toulouse University Hospital included sixty patients scheduled for custom-made silicone implants correction. Respiratory function (pulmonary function tests (FPTs)) and exercise capacity (VO2 max) were measured before surgery.

RESULTS:

Before surgery, no (0/60) restrictive lung disease was detected, with a mean total lung capacity (TLC) of 98.5% of predicted value (IC 95%; 80.4-137). Median VO2 max (n=56) was normal (89% predicted), with no cardiac limitation.

CONCLUSION:

In this cohort, PE had no impact on respiratory function nor exercise capacity. In patients without cardiac or respiratory effects of PE, silicone implants should be considered the preferred approach as it adequately addressed patients' main complaint of low self-esteem.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tórax en Embudo Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tórax en Embudo Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2024 Tipo del documento: Article