Color changes of nanocomposites used for clear aligner attachments: an in vitro study.
Özsoy, Serhat; Pamukçu, Hande; Polat-Özsoy, Ömür; Ates, Ece Mersan.
  • Özsoy S; Private practice, Ankara, Turkey.
  • Pamukçu H; Department of Orthodontics, Faculty of Dentistry, Baskent University, Yukaribahçelievler Mah. 82. Sokak No:26, 06490, Bahçelievler Ankara, Turkey. handeorkun@yahoo.com.
  • Polat-Özsoy Ö; Private practice, Ankara, Turkey.
  • Ates EM; Department of Orthodontics, Faculty of Dentistry, Izmir Tinaztepe University, Aydogdu Mah. 1267/1 Sokak No:4, Buca, Izmir, Turkey.
J Orofac Orthop ; 84(Suppl 3): 266-275, 2023 Oct.
Article en En | MEDLINE | ID: mdl-36912962
ABSTRACT

PURPOSE:

The purpose of this study was to compare the color changes of two different nanocomposites used for two different designs of clear aligner attachments.

METHODS:

In all, 120 human premolars were embedded in 12 upper dental models with 10 premolars in each model. Models were scanned and attachments were digitally designed. Conventional attachments (CA) were prepared for the first six models and optimized multiplane attachments (OA) were prepared for the other six models with packable composite (PC) on the right quadrant and flowable composite (FC) on the left quadrant of each model. The models were subjected to 2000 thermal cycles at 5 °C/55 °C and then consecutively immersed in the five different staining solutions each for 48 h to simulate external discoloration. Color measurements were taken with a spectrophotometer. Color changes (∆E*ab) of the attachments before and after immersion were compared with the Commission Internationale de l'Éclairage L*a*b* (CIELAB) color space approach.

RESULTS:

When ∆E*ab values were examined, no significant difference was observed between the groups according to the attachment type (P > 0.05). After the coloration process, the flowable composite group showed less coloration than the packable composite group for both attachment designs (P < 0.05). Color difference values after the staining procedure were significantly higher in the CA-PC and OA-PC groups compared to the CA-FC and OA-FC groups (P < 0.05).

CONCLUSION:

Color change of the packable nanocomposite was more pronounced than that of the flowable nanocomposite for both attachment designs. Therefore, clear aligner attachments created using flowable nanocomposite can be recommended, especially in the anterior region where esthetics are important for the patient.